Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

121

matching recommendations
Reset
NAICS 3359 Other Electrical Equipment and Component Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SU0362 # 01 Y:2014 01 2014 INSTALL / REPAIR INSULATION ON STEAM LINES $1,295 $202 Implemented
SU0362 # 02 Y:2014 02 2014 INSTALL OCCUPANCY SENSORS $2,464 $1,840 Implemented
SU0362 # 03 Y:2014 03 2014 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $1,404 $2,959 Implemented
SU0362 # 04 Y:2014 04 2014 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $8,593 $15,784 Not Implemented
SU0362 # 05 Y:2014 05 2014 ELIMINATE/REDUCE AN OPERATION $4,540 $15,840 Not Implemented
SU0362 # 06 Y:2014 06 2014 UPGRADE OBSOLETE EQUIPMENT $289 $1,250 Implemented
SU0361 # 01 Y:2014 01 2014 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,135 $0 Implemented
SU0361 # 02 Y:2014 02 2014 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $376 $0 Not Implemented
SU0361 # 03 Y:2014 03 2014 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $10,756 $1,527 Implemented
SU0361 # 04 Y:2014 04 2014 INSTALL / REPAIR INSULATION ON STEAM LINES $3,508 $849 Implemented
SU0361 # 05 Y:2014 05 2014 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $1,288 $2,716 Implemented
SU0361 # 06 Y:2014 06 2014 UPGRADE OBSOLETE EQUIPMENT $512 $1,800 Implemented
SU0361 # 07 Y:2014 07 2014 ELIMINATE/REDUCE AN OPERATION $8,503 $41,760 Not Implemented
SU0361 # 08 Y:2014 08 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,075 $35,370 Implemented
SU0306 # 01 Y:2011 01 2011 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $19,413 $0 Implemented
SU0306 # 02 Y:2011 02 2011 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,375 $0 Implemented
SU0306 # 03 Y:2011 03 2011 RECOVER AND REUSE SPENT ACID BATHS $49,465 $4,029 Implemented
SU0306 # 04 Y:2011 04 2011 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,901 $337 Implemented
SU0306 # 05 Y:2011 05 2011 RECOVER AND REUSE COOLING WATER $32,137 $12,052 Implemented
SU0306 # 06 Y:2011 06 2011 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $8,700 $35,000 Not Implemented
SU0306 # 07 Y:2011 07 2011 OPTIMIZE PLANT POWER FACTOR $8,914 $55,516 Not Implemented
SU0267 # 01 Y:2008 01 2008 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $7,704 $0 Not Implemented
SU0267 # 02 Y:2008 02 2008 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $664 $0 Implemented
SU0267 # 03 Y:2008 03 2008 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $730 $0 Implemented
SU0267 # 04 Y:2008 04 2008 DISCONNECT BALLASTS $209 $0 Not Implemented