Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
66
matching recommendationsNAICS | 3359 | Other Electrical Equipment and Component Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0720 # 07 Y:2013 | 07 | 2013 | REDUCE VENTILATION AIR | $4,116 | $2,500 | Implemented |
MA0720 # 02 Y:2013 | 02 | 2013 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $10,748 | $1,000 | Implemented |
MA0720 # 01 Y:2013 | 01 | 2013 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $13,659 | $200 | Implemented |
MA0720 # 03 Y:2013 | 03 | 2013 | OPTIMIZE PLANT POWER FACTOR | $10,121 | $12,390 | Implemented |
MA0720 # 04 Y:2013 | 04 | 2013 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $8,238 | $10,000 | Implemented |
MA0720 # 05 Y:2013 | 05 | 2013 | REDUCE VENTILATION AIR | $7,186 | $2,510 | Not Implemented |
MA0720 # 06 Y:2013 | 06 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,682 | $500 | Not Implemented |
MA0720 # 08 Y:2013 | 08 | 2013 | REDUCE VENTILATION AIR | $2,479 | $6,235 | Not Implemented |
OR0620 # 02 Y:2013 | 02 | 2013 | REDUCE VENTILATION AIR | $28,525 | $3,200 | Not Implemented |
OR0620 # 05 Y:2013 | 05 | 2013 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $584 | $2,554 | Not Implemented |
OR0620 # 03 Y:2013 | 03 | 2013 | INSULATE BARE EQUIPMENT | $456 | $163 | Not Implemented |
OR0620 # 04 Y:2013 | 04 | 2013 | MODIFY STARTUP/SHUTDOWN TIMES | $442 | $481 | Not Implemented |
OR0620 # 01 Y:2013 | 01 | 2013 | PURCHASE EQUIPMENT INSTEAD OF LEASING | $50,574 | $68,750 | Not Implemented |
OR0619 # 04 Y:2013 | 04 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $679 | $1,677 | Not Implemented |
OR0619 # 02 Y:2013 | 02 | 2013 | REDUCE FLUID FLOW RATES | $2,879 | $6,200 | Not Implemented |
OR0619 # 03 Y:2013 | 03 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,300 | $50,000 | Not Implemented |
OR0619 # 06 Y:2013 | 06 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,550 | $13,225 | Not Implemented |
OR0619 # 05 Y:2013 | 05 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,667 | $2,342 | Not Implemented |
OR0619 # 01 Y:2013 | 01 | 2013 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $7,073 | $2,342 | Not Implemented |
NC0488 # 08 Y:2013 | 08 | 2013 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $496 | $0 | Not Implemented |
NC0488 # 07 Y:2013 | 07 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,980 | $19,622 | Implemented |
NC0488 # 06 Y:2013 | 06 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $323 | $600 | Implemented |
NC0488 # 04 Y:2013 | 04 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $741 | $2,535 | Not Implemented |
NC0488 # 03 Y:2013 | 03 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $627 | $100 | Implemented |
NC0488 # 01 Y:2013 | 01 | 2013 | USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS | $83,386 | $250,000 | Not Implemented |