Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
59
matching recommendationsNAICS | 33593 | Wiring Device Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0094 # 07 Y:2004 | 07 | 2004 | USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES | $11,093 | $2,056 | Implemented |
MI0094 # 06 Y:2004 | 06 | 2004 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $1,385 | $0 | Not Implemented |
MI0094 # 05 Y:2004 | 05 | 2004 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $1,547 | $0 | Not Implemented |
MI0094 # 04 Y:2004 | 04 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $9,418 | $92 | Implemented |
MI0094 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $-177 | $590 | Implemented |
MI0094 # 02 Y:2004 | 02 | 2004 | REDUCE DEFECTS BY REDUCING PRODUCT TIPPING | $95,473 | $150 | Implemented |
MI0094 # 01 Y:2004 | 01 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $24,368 | $2,300 | Implemented |
MI0093 # 07 Y:2004 | 07 | 2004 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $8,755 | $510 | Implemented |
MI0093 # 01 Y:2004 | 01 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $2,620 | $0 | Not Implemented |
MI0093 # 02 Y:2004 | 02 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $44,199 | $0 | Not Implemented |
MI0093 # 03 Y:2004 | 03 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $553 | $0 | Not Implemented |
MI0093 # 04 Y:2004 | 04 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,800 | $0 | Not Implemented |
MI0093 # 05 Y:2004 | 05 | 2004 | INCREASE USE OF AUTOMATION | $28,521 | $0 | Not Implemented |
MI0093 # 06 Y:2004 | 06 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,994 | $0 | Not Implemented |
MI0093 # 08 Y:2004 | 08 | 2004 | INSTALL ROTATING CAROUSELS TO REDUCE SET-UP TIMES | $23,333 | $21,000 | Implemented |
MI0093 # 09 Y:2004 | 09 | 2004 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $12,561 | $0 | Not Implemented |
UF0352 # 04 Y:2004 | 04 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,546 | $1,000 | Not Implemented |
UF0352 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,849 | $2,250 | Not Implemented |
UF0352 # 02 Y:2004 | 02 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $13,502 | $15,442 | Not Implemented |
UF0352 # 03 Y:2004 | 03 | 2004 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $3,562 | $0 | Not Implemented |
UF0352 # 07 Y:2004 | 07 | 2004 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $6,509 | $2,200 | Not Implemented |
UF0352 # 05 Y:2004 | 05 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,832 | $0 | Not Implemented |
UF0352 # 09 Y:2004 | 09 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,302 | $1,278 | Not Implemented |
UF0352 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $813 | $1,400 | Not Implemented |
UF0352 # 08 Y:2004 | 08 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,009 | $0 | Not Implemented |