Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
6,773
matching recommendationsNAICS | 336 | Transportation Equipment Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0103 # 04 Y:2013 | 04 | 2013 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,052 | $120 | Implemented |
UA0103 # 05 Y:2013 | 05 | 2013 | INSTALL TIMERS AND/OR THERMOSTATS | $1,143 | $660 | Implemented |
UA0103 # 06 Y:2013 | 06 | 2013 | DISCONNECT BALLASTS | $4,145 | $2,643 | Not Implemented |
UA0103 # 07 Y:2013 | 07 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,742 | $800 | Not Implemented |
UA0103 # 08 Y:2013 | 08 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,290 | $1,800 | Not Implemented |
BS0017 # 01 Y:2013 | 01 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $268 | $182 | Implemented |
BS0017 # 02 Y:2013 | 02 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $391 | $977 | Implemented |
BS0017 # 03 Y:2013 | 03 | 2013 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $1,029 | $4,500 | Implemented |
BS0017 # 04 Y:2013 | 04 | 2013 | INSTALL OCCUPANCY SENSORS | $207 | $48 | Implemented |
BS0017 # 05 Y:2013 | 05 | 2013 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $998 | $1,134 | Not Implemented |
BS0017 # 06 Y:2013 | 06 | 2013 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $2,115 | $2,167 | Implemented |
IA0497 # 01 Y:2013 | 01 | 2013 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $19,923 | $46,094 | Implemented |
IA0497 # 02 Y:2013 | 02 | 2013 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $1,463 | $2,391 | Not Implemented |
IA0497 # 03 Y:2013 | 03 | 2013 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,575 | $3,675 | Not Implemented |
IA0497 # 04 Y:2013 | 04 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,214 | $1,720 | Implemented |
IA0497 # 05 Y:2013 | 05 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,881 | $4,000 | Not Implemented |
IA0497 # 06 Y:2013 | 06 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,468 | $1,500 | Implemented |
IA0497 # 07 Y:2013 | 07 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $7,000 | $7,560 | Not Implemented |
UA0102 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $50,854 | $94,049 | Implemented |
UA0102 # 02 Y:2013 | 02 | 2013 | DISCONNECT BALLASTS | $9,077 | $2,400 | Not Implemented |
UA0102 # 03 Y:2013 | 03 | 2013 | INSTALL OCCUPANCY SENSORS | $2,868 | $3,530 | Implemented |
UA0102 # 04 Y:2013 | 04 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,113 | $4,070 | Not Implemented |
UA0102 # 05 Y:2013 | 05 | 2013 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $20,898 | $56,750 | Implemented |
UA0102 # 06 Y:2013 | 06 | 2013 | INSTALL TIMERS AND/OR THERMOSTATS | $9,708 | $336 | Implemented |
UA0102 # 07 Y:2013 | 07 | 2013 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $5,742 | $4,348 | Not Implemented |