Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
6,773
matching recommendationsNAICS | 336 | Transportation Equipment Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA3024 # 02 Y:2012 | 02 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $85,875 | $23,130 | Not Implemented |
UA3024 # 03 Y:2012 | 03 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $50,436 | $2,500 | Implemented |
UA3024 # 04 Y:2012 | 04 | 2012 | UPGRADE CONTROLS ON COMPRESSORS | $15,748 | $2,000 | Not Implemented |
UA3024 # 05 Y:2012 | 05 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $42,972 | $54,662 | Not Implemented |
UA3024 # 06 Y:2012 | 06 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $22,128 | $66,849 | Not Implemented |
UA3023 # 01 Y:2012 | 01 | 2012 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $90,505 | $55,107 | Not Implemented |
UA3023 # 02 Y:2012 | 02 | 2012 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $27,110 | $2,162 | Not Implemented |
UA3023 # 03 Y:2012 | 03 | 2012 | INSTALL TIMERS AND/OR THERMOSTATS | $9,242 | $680 | Not Implemented |
UA3023 # 04 Y:2012 | 04 | 2012 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,914 | $180 | Implemented |
UA3023 # 05 Y:2012 | 05 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $28,652 | $2,400 | Not Implemented |
UA3023 # 06 Y:2012 | 06 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $26,924 | $9,695 | Not Implemented |
UA3023 # 07 Y:2012 | 07 | 2012 | DISCONNECT BALLASTS | $6,783 | $1,013 | Implemented |
UA3023 # 08 Y:2012 | 08 | 2012 | DISCONNECT BALLASTS | $4,820 | $810 | Implemented |
UA3023 # 09 Y:2012 | 09 | 2012 | DISCONNECT BALLASTS | $3,927 | $810 | Implemented |
UA3023 # 10 Y:2012 | 10 | 2012 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $1,216 | $430 | Not Implemented |
NC0472 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,563 | $16,950 | Implemented |
NC0472 # 02 Y:2012 | 02 | 2012 | INSTALL OCCUPANCY SENSORS | $845 | $1,125 | Not Implemented |
NC0472 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $84 | $200 | Not Implemented |
NC0472 # 04 Y:2012 | 04 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $188 | $50 | Implemented |
NC0472 # 05 Y:2012 | 05 | 2012 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $24 | $0 | Implemented |
BD0417 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $661 | $966 | Implemented |
BD0417 # 02 Y:2012 | 02 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $889 | $10 | Not Implemented |
BD0417 # 03 Y:2012 | 03 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,168 | $300 | Not Implemented |
BD0417 # 04 Y:2012 | 04 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $38,469 | $5,000 | Implemented |
BD0417 # 05 Y:2012 | 05 | 2012 | USE SYNTHETIC LUBRICANT | $1,301 | $500 | Not Implemented |