Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
6,763
matching recommendationsNAICS | 336 | Transportation Equipment Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0835 # 07 Y:2011 | 07 | 2011 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $15,451 | $12,000 | Not Implemented |
UD0835 # 08 Y:2011 | 08 | 2011 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $13,470 | $14,800 | Not Implemented |
DL0068 # 01 Y:2011 | 01 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $14,500 | $200 | Implemented |
DL0068 # 02 Y:2011 | 02 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $15,200 | $3,200 | Implemented |
DL0068 # 03 Y:2011 | 03 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $51,300 | $12,000 | Implemented |
DL0068 # 04 Y:2011 | 04 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $182,000 | $17,000 | Not Implemented |
DL0068 # 05 Y:2011 | 05 | 2011 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $21,659 | $4,300 | Implemented |
DL0068 # 06 Y:2011 | 06 | 2011 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $51,400 | $10,000 | Implemented |
DL0068 # 07 Y:2011 | 07 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,315 | $15,000 | Not Implemented |
DL0068 # 08 Y:2011 | 08 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $183,000 | $600,000 | Not Implemented |
DL0068 # 09 Y:2011 | 09 | 2011 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $32,300 | $200 | Implemented |
TT0060 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,900 | $23,000 | Not Implemented |
TT0060 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,000 | $39,900 | Not Implemented |
TT0060 # 03 Y:2011 | 03 | 2011 | INSTALL EQUIPMENT TO UTILIZE WASTE FUEL | $51,500 | $98,000 | Not Implemented |
TT0060 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,700 | $4,900 | Not Implemented |
TT0060 # 05 Y:2011 | 05 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,200 | $4,700 | Not Implemented |
TT0060 # 06 Y:2011 | 06 | 2011 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $8,700 | $8,000 | Not Implemented |
TT0060 # 07 Y:2011 | 07 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $28,000 | $53,000 | Not Implemented |
TT0060 # 08 Y:2011 | 08 | 2011 | REVISE SMOKE CLEANUP FROM OPERATIONS | $22,900 | $20,000 | Not Implemented |
TT0060 # 09 Y:2011 | 09 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $9,800 | $200 | Not Implemented |
TT0060 # 10 Y:2011 | 10 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $3,700 | $1,600 | Not Implemented |
TT0060 # 11 Y:2011 | 11 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $500 | $600 | Not Implemented |
TT0060 # 12 Y:2011 | 12 | 2011 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,280 | $0 | Not Implemented |
MI0206 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,265 | $37,814 | Implemented |
MI0206 # 02 Y:2011 | 02 | 2011 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $10,476 | $44,779 | Implemented |