Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
6,754
matching recommendationsNAICS | 336 | Transportation Equipment Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0374 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $733 | $1 | Implemented |
IA0374 # 09 Y:2005 | 09 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $233 | $548 | Implemented |
IA0374 # 10 Y:2005 | 10 | 2005 | USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS | $20,227 | $341 | Not Implemented |
IA0374 # 11 Y:2005 | 11 | 2005 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $16,269 | $67 | Implemented |
CO0572 # 01 Y:2005 | 01 | 2005 | INSTALL SKYLIGHTS | $9,660 | $40,800 | Not Implemented |
CO0572 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,460 | $7,700 | Not Implemented |
CO0572 # 03 Y:2005 | 03 | 2005 | USE SOLAR HEAT TO HEAT MAKE-UP AIR | $2,480 | $30,770 | Not Implemented |
CO0572 # 04 Y:2005 | 04 | 2005 | INSTALL OCCUPANCY SENSORS | $2,420 | $7,570 | Not Implemented |
CO0572 # 05 Y:2005 | 05 | 2005 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,370 | $1,000 | Not Implemented |
CO0572 # 06 Y:2005 | 06 | 2005 | INSTALL OCCUPANCY SENSORS | $560 | $1,760 | Not Implemented |
UM0289 # 01 Y:2005 | 01 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $164,291 | $74,114 | Implemented |
UM0289 # 02 Y:2005 | 02 | 2005 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $56,272 | $85,815 | Not Implemented |
UM0289 # 03 Y:2005 | 03 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $37,184 | $11,610 | Implemented |
UM0289 # 04 Y:2005 | 04 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $16,576 | $2,500 | Implemented |
UM0289 # 05 Y:2005 | 05 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $9,600 | $1,400 | Implemented |
UM0289 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $859 | $2,663 | Not Implemented |
UM0288 # 01 Y:2005 | 01 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,386 | $10,000 | Implemented |
UM0288 # 02 Y:2005 | 02 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,865 | $150 | Implemented |
UM0288 # 03 Y:2005 | 03 | 2005 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,004 | $400 | Implemented |
UM0288 # 04 Y:2005 | 04 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $895 | $1,000 | Not Implemented |
UM0288 # 05 Y:2005 | 05 | 2005 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $656 | $0 | Implemented |
UM0288 # 06 Y:2005 | 06 | 2005 | REDUCE VENTILATION AIR | $616 | $150 | Implemented |
UM0288 # 07 Y:2005 | 07 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $159 | $25 | Implemented |
UM0288 # 08 Y:2005 | 08 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $141 | $300 | Not Implemented |
UM0288 # 09 Y:2005 | 09 | 2005 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $130 | $50 | Not Implemented |