Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
6,754
matching recommendationsNAICS | 336 | Transportation Equipment Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0354 # 01 Y:2004 | 01 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $48,587 | $63,488 | Implemented |
UF0354 # 02 Y:2004 | 02 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $19,414 | $0 | Implemented |
UF0354 # 03 Y:2004 | 03 | 2004 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $18,795 | $62,620 | Not Implemented |
UF0354 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,169 | $745 | Not Implemented |
UF0354 # 05 Y:2004 | 05 | 2004 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $7,962 | $31,000 | Implemented |
UF0354 # 06 Y:2004 | 06 | 2004 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $6,140 | $779 | Not Implemented |
UF0354 # 07 Y:2004 | 07 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,543 | $0 | Implemented |
UF0354 # 08 Y:2004 | 08 | 2004 | ADD AREA LIGHTING SWITCHES | $2,354 | $11,495 | Not Implemented |
UF0354 # 09 Y:2004 | 09 | 2004 | RECYCLE FLUORESCENT LAMPS | $2,883 | $3,496 | Not Implemented |
GT0794 # 01 Y:2004 | 01 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $15,414 | $30,000 | n/a |
GT0794 # 02 Y:2004 | 02 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,785 | $3,525 | Not Implemented |
GT0794 # 03 Y:2004 | 03 | 2004 | INSTALL OCCUPANCY SENSORS | $595 | $765 | Not Implemented |
GT0794 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,306 | $2,046 | Implemented |
GT0794 # 05 Y:2004 | 05 | 2004 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $5,022 | $3,380 | Not Implemented |
GT0794 # 06 Y:2004 | 06 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,490 | $2,500 | Implemented |
GT0794 # 07 Y:2004 | 07 | 2004 | INSTALL TIMERS AND/OR THERMOSTATS | $729 | $1,500 | Not Implemented |
GT0794 # 08 Y:2004 | 08 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,773 | $4,900 | Not Implemented |
GT0794 # 09 Y:2004 | 09 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,609 | $0 | Implemented |
OK0699 # 01 Y:2004 | 01 | 2004 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $9,780 | $6,150 | Implemented |
OK0699 # 02 Y:2004 | 02 | 2004 | AIR CONDITION ONLY SPACE NECESSARY | $8,145 | $24,175 | Implemented |
OK0699 # 03 Y:2004 | 03 | 2004 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $5,446 | $23,400 | Implemented |
OK0699 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,440 | $18,681 | Implemented |
OK0699 # 05 Y:2004 | 05 | 2004 | INSTALL SET-BACK TIMERS | $6,489 | $3,960 | Implemented |
OK0699 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $418 | $520 | Implemented |
OK0699 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $324 | $707 | Implemented |