Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

6,754

matching recommendations
Reset
NAICS 336 Transportation Equipment Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LL0203 # 07 Y:2004 07 2004 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $4,000 $60 Implemented
LL0203 # 08 Y:2004 08 2004 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $3,870 $1,014 Implemented
LL0202 # 01 Y:2004 01 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $69,470 $20,680 Implemented
LL0202 # 02 Y:2004 02 2004 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $14,991 $16,845 Not Implemented
LL0202 # 03 Y:2004 03 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $9,972 $500 Implemented
LL0202 # 04 Y:2004 04 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $6,675 $30 Implemented
LL0202 # 05 Y:2004 05 2004 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $3,376 $135 Not Implemented
LL0202 # 06 Y:2004 06 2004 INSTALL OCCUPANCY SENSORS $1,329 $390 Not Implemented
LL0202 # 07 Y:2004 07 2004 USE PHOTOCELL CONTROLS $726 $150 Not Implemented
LL0202 # 08 Y:2004 08 2004 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $442 $198 Not Implemented
NC0290 # 01 Y:2004 01 2004 INSTALL REFRIGERATION SYSTEM TO COOL PRODUCT $145,703 $276,000 Implemented
NC0290 # 02 Y:2004 02 2004 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING $9,371 $4,079 Not Implemented
NC0290 # 03 Y:2004 03 2004 RECOVER WASTE HEAT FROM EQUIPMENT $8,085 $5,500 Not Implemented
NC0290 # 04 Y:2004 04 2004 INSULATE BARE EQUIPMENT $2,865 $9,174 Not Implemented
NC0290 # 05 Y:2004 05 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,206 $2,269 Not Implemented
NC0290 # 06 Y:2004 06 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $612 $100 Implemented
NC0290 # 07 Y:2004 07 2004 INSTALL / REPAIR INSULATION ON STEAM LINES $10,346 $2,533 Implemented
NC0297 # 01 Y:2004 01 2004 ADJUST BURNERS FOR EFFICIENT OPERATION $2,652 $1,000 Implemented
NC0297 # 02 Y:2004 02 2004 KEEP BOILER TUBES CLEAN $1,635 $800 Implemented
NC0297 # 03 Y:2004 03 2004 INSULATE FEEDWATER TANK $547 $1,500 Implemented
NC0297 # 04 Y:2004 04 2004 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $13,319 $1,950 Implemented
NC0297 # 05 Y:2004 05 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $846 $1,400 Implemented
NC0297 # 06 Y:2004 06 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,920 $4,114 Implemented
NC0297 # 07 Y:2004 07 2004 USE PHOTOCELL CONTROLS $100 $130 Implemented
UU0066 # 01 Y:2004 01 2004 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $2,690 $3,000 Not Implemented