Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
6,754
matching recommendationsNAICS | 336 | Transportation Equipment Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD1030 # 03 Y:2021 | 03 | 2021 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $11,468 | $4,319 | Not Implemented |
UD1030 # 04 Y:2021 | 04 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,026 | $340 | Implemented |
NC0669 # 01 Y:2021 | 01 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,041 | $11,374 | n/a |
NC0669 # 02 Y:2021 | 02 | 2021 | RECOVER WASTE HEAT FROM EQUIPMENT | $16,266 | $40,000 | n/a |
NC0669 # 03 Y:2021 | 03 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $854 | $300 | n/a |
NC0669 # 04 Y:2021 | 04 | 2021 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $8,310 | $30,000 | n/a |
UA0243 # 01 Y:2021 | 01 | 2021 | INSTALL OCCUPANCY SENSORS | $6,816 | $22,649 | Not Implemented |
UA0243 # 02 Y:2021 | 02 | 2021 | USE PHOTOCELL CONTROLS | $8,709 | $24,348 | Not Implemented |
UA0243 # 03 Y:2021 | 03 | 2021 | OPTIMIZE PLANT POWER FACTOR | $45,219 | $10,941 | Implemented |
UA0243 # 04 Y:2021 | 04 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,058 | $9,682 | Implemented |
UA0243 # 05 Y:2021 | 05 | 2021 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $2,529 | $100 | Not Implemented |
UA0243 # 06 Y:2021 | 06 | 2021 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,133 | $4,930 | Not Implemented |
SU0507 # 01 Y:2021 | 01 | 2021 | PAY BILLS ON TIME TO AVOID LATE FEES | $1,720 | $0 | Implemented |
SU0507 # 02 Y:2021 | 02 | 2021 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $23,973 | $120 | Not Implemented |
SU0507 # 03 Y:2021 | 03 | 2021 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $7,147 | $120 | Not Implemented |
SU0507 # 04 Y:2021 | 04 | 2021 | REDUCE VENTILATION AIR | $4,625 | $882 | Not Implemented |
SU0507 # 05 Y:2021 | 05 | 2021 | INSTALL / REPAIR INSULATION ON STEAM LINES | $191 | $203 | Implemented |
SU0507 # 06 Y:2021 | 06 | 2021 | ELIMINATE/REDUCE AN OPERATION | $2,822 | $3,300 | Implemented |
SU0507 # 07 Y:2021 | 07 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,661 | $7,939 | Not Implemented |
SU0507 # 08 Y:2021 | 08 | 2021 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $10,521 | $22,840 | Not Implemented |
SU0507 # 09 Y:2021 | 09 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $375 | $1,259 | Implemented |
SD0613 # 01 Y:2021 | 01 | 2021 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $7,677 | $16,500 | Implemented |
SD0613 # 02 Y:2021 | 02 | 2021 | SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING | $8,370 | $5,000 | Implemented |
SD0613 # 03 Y:2021 | 03 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,201 | $1,065 | Implemented |
SD0613 # 04 Y:2021 | 04 | 2021 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $590 | $1,500 | Not Implemented |