Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
412
matching recommendationsNAICS | 336 | Transportation Equipment Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0504 # 06 Y:2017 | 06 | 2017 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $9,360 | $3,600 | Not Implemented |
MI0297 # 01 Y:2016 | 01 | 2016 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $97,105 | $82,600 | Not Implemented |
MI0297 # 02 Y:2016 | 02 | 2016 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $65,063 | $200,000 | Not Implemented |
MI0297 # 03 Y:2016 | 03 | 2016 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $40,957 | $1,120 | Not Implemented |
MI0297 # 04 Y:2016 | 04 | 2016 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $27,925 | $1,400 | Not Implemented |
MI0297 # 05 Y:2016 | 05 | 2016 | RECOVER WASTE HEAT FROM EQUIPMENT | $23,144 | $7,000 | Implemented |
MI0297 # 06 Y:2016 | 06 | 2016 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $21,747 | $40 | Not Implemented |
MI0297 # 07 Y:2016 | 07 | 2016 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $21,352 | $22,281 | Implemented |
MI0297 # 08 Y:2016 | 08 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $21,133 | $1,660 | Implemented |
MI0297 # 09 Y:2016 | 09 | 2016 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $9,631 | $16,156 | Not Implemented |
MI0297 # 10 Y:2016 | 10 | 2016 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $5,934 | $10,031 | Not Implemented |
MI0297 # 11 Y:2016 | 11 | 2016 | INSTALL OCCUPANCY SENSORS | $5,116 | $884 | Not Implemented |
MI0297 # 12 Y:2016 | 12 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,442 | $2,628 | Implemented |
MI0297 # 13 Y:2016 | 13 | 2016 | USE PHOTOCELL CONTROLS | $781 | $240 | Not Implemented |
MI0297 # 14 Y:2016 | 14 | 2016 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $335 | $944 | Implemented |
MI0278 # 01 Y:2015 | 01 | 2015 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $103,740 | $220,000 | Not Implemented |
MI0278 # 02 Y:2015 | 02 | 2015 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $94,012 | $102,610 | Not Implemented |
MI0278 # 03 Y:2015 | 03 | 2015 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $45,923 | $79,106 | Implemented |
MI0278 # 04 Y:2015 | 04 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,431 | $9,248 | Implemented |
MI0278 # 05 Y:2015 | 05 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,235 | $1,660 | Implemented |
MI0278 # 06 Y:2015 | 06 | 2015 | INSTALL OCCUPANCY SENSORS | $4,706 | $2,901 | Implemented |
MI0278 # 07 Y:2015 | 07 | 2015 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,804 | $480 | Implemented |
MI0278 # 08 Y:2015 | 08 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,391 | $8,360 | Implemented |
MI0278 # 09 Y:2015 | 09 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,181 | $40 | Implemented |
MI0278 # 10 Y:2015 | 10 | 2015 | USE OPTIMUM THICKNESS INSULATION | $711 | $610 | Implemented |