Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
6,754
matching recommendationsNAICS | 336 | Transportation Equipment Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0229 # 06 Y:2019 | 06 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,229 | $9,752 | Implemented |
MZ0282 # 01 Y:2019 | 01 | 2019 | INSTALL SPECTRAL REFLECTORS / DELAMP | $586 | $472 | Implemented |
MZ0282 # 02 Y:2019 | 02 | 2019 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $6,947 | $24,000 | Not Implemented |
MZ0282 # 03 Y:2019 | 03 | 2019 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,896 | $2,300 | Not Implemented |
MZ0282 # 04 Y:2019 | 04 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,849 | $320 | Not Implemented |
MZ0282 # 05 Y:2019 | 05 | 2019 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $287,984 | $1,030,500 | Not Implemented |
MZ0282 # 06 Y:2019 | 06 | 2019 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $3,100 | $14,000 | Not Implemented |
MZ0282 # 07 Y:2019 | 07 | 2019 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,721 | $7,200 | Implemented |
MZ0282 # 08 Y:2019 | 08 | 2019 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $53,310 | $16,200 | Implemented |
MZ0282 # 09 Y:2019 | 09 | 2019 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,909 | $680 | Implemented |
MZ0282 # 10 Y:2019 | 10 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,466 | $2,964 | Not Implemented |
MZ0282 # 11 Y:2019 | 11 | 2019 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $5,699 | $18,720 | Not Implemented |
SU0486 # 01 Y:2019 | 01 | 2019 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $359 | $0 | Not Implemented |
SU0486 # 02 Y:2019 | 02 | 2019 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,163 | $99 | Not Implemented |
SU0486 # 03 Y:2019 | 03 | 2019 | REDUCE VENTILATION AIR | $4,494 | $890 | Not Implemented |
SU0486 # 04 Y:2019 | 04 | 2019 | ELIMINATE/REDUCE AN OPERATION | $6,082 | $2,288 | Not Implemented |
SU0486 # 05 Y:2019 | 05 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $26,788 | $21,904 | Not Implemented |
SU0486 # 06 Y:2019 | 06 | 2019 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $869 | $845 | Not Implemented |
SU0486 # 07 Y:2019 | 07 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $802 | $857 | Implemented |
SU0486 # 08 Y:2019 | 08 | 2019 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $411 | $839 | Implemented |
SU0486 # 09 Y:2019 | 09 | 2019 | INSTALL OCCUPANCY SENSORS | $767 | $2,060 | Not Implemented |
UA0215 # 01 Y:2019 | 01 | 2019 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $12,317 | $50 | Implemented |
UA0215 # 02 Y:2019 | 02 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,328 | $11,266 | Not Implemented |
UA0215 # 03 Y:2019 | 03 | 2019 | INSTALL OCCUPANCY SENSORS | $663 | $539 | Not Implemented |
UA0215 # 04 Y:2019 | 04 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $816 | $50 | Implemented |