Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

135

matching recommendations
Reset
NAICS 336111 Automobile Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0941 # 10 Y:2016 10 2016 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $645 $0 Implemented
UD0941 # 11 Y:2016 11 2016 USE RADIANT HEATER FOR SPOT HEATING $4,035 $3,850 Not Implemented
UD0941 # 12 Y:2016 12 2016 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $5,616 $11,550 Not Implemented
UD0941 # 13 Y:2016 13 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,165 $35,457 Implemented
UD0941 # 14 Y:2016 14 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,738 $14,851 Implemented
SU0320 # 01 Y:2012 01 2012 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,185 $0 Not Implemented
SU0320 # 02 Y:2012 02 2012 REDUCE VENTILATION AIR $7,403 $5,019 Not Implemented
SU0320 # 03 Y:2012 03 2012 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $18,749 $42,038 Not Implemented
SU0320 # 04 Y:2012 04 2012 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $391 $1,332 Not Implemented
SU0320 # 05 Y:2012 05 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,671 $37,046 Not Implemented
SU0320 # 06 Y:2012 06 2012 MAKE A NEW BY-PRODUCT $21,685 $100,000 Not Implemented
SU0320 # 07 Y:2012 07 2012 ELIMINATE/REDUCE AN OPERATION $2,644 $15,840 Not Implemented
DL0073 # 01 Y:2011 01 2011 BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT $904,000 $2,850,000 Not Implemented
DL0073 # 02 Y:2011 02 2011 REPLACE BOILER $420,000 $408,000 Not Implemented
DL0073 # 03 Y:2011 03 2011 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $19,700 $6,400 Not Implemented
DL0068 # 01 Y:2011 01 2011 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $14,500 $200 Implemented
DL0068 # 02 Y:2011 02 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $15,200 $3,200 Implemented
DL0068 # 03 Y:2011 03 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $51,300 $12,000 Implemented
DL0068 # 04 Y:2011 04 2011 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $182,000 $17,000 Not Implemented
DL0068 # 05 Y:2011 05 2011 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $21,659 $4,300 Implemented
DL0068 # 06 Y:2011 06 2011 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $51,400 $10,000 Implemented
DL0068 # 07 Y:2011 07 2011 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,315 $15,000 Not Implemented
DL0068 # 08 Y:2011 08 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $183,000 $600,000 Not Implemented
DL0068 # 09 Y:2011 09 2011 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $32,300 $200 Implemented
MS0340 # 01 Y:2009 01 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,689 $21,753 Implemented