Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
262
matching recommendationsNAICS | 3363 | Motor Vehicle Parts Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0082 # 01 Y:2012 | 01 | 2012 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $89,005 | $0 | Not Implemented |
UA0082 # 02 Y:2012 | 02 | 2012 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $25,747 | $24,000 | Not Implemented |
UA0082 # 03 Y:2012 | 03 | 2012 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $21,616 | $1,199 | Not Implemented |
UA0082 # 04 Y:2012 | 04 | 2012 | INSTALL TIMERS AND/OR THERMOSTATS | $2,439 | $0 | Not Implemented |
UA0082 # 05 Y:2012 | 05 | 2012 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $1,097 | $171 | Not Implemented |
UA0082 # 06 Y:2012 | 06 | 2012 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $17,850 | $26,100 | Not Implemented |
UA0082 # 07 Y:2012 | 07 | 2012 | UPGRADE CONTROLS ON COMPRESSORS | $19,536 | $6,566 | Not Implemented |
UA0082 # 08 Y:2012 | 08 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,883 | $7,495 | Implemented |
UA0082 # 09 Y:2012 | 09 | 2012 | OPTIMIZE PLANT POWER FACTOR | $18,443 | $21,400 | Not Implemented |
UA0082 # 10 Y:2012 | 10 | 2012 | INSTALL OCCUPANCY SENSORS | $2,406 | $116 | Not Implemented |
UA0078 # 01 Y:2012 | 01 | 2012 | BURN A LESS EXPENSIVE GRADE OF FUEL | $217,328 | $9,277 | Not Implemented |
UA0078 # 02 Y:2012 | 02 | 2012 | OPTIMIZE PLANT POWER FACTOR | $59,117 | $13,031 | Not Implemented |
UA0078 # 03 Y:2012 | 03 | 2012 | UPGRADE CONTROLS ON COMPRESSORS | $15,318 | $30,000 | Not Implemented |
UA0078 # 04 Y:2012 | 04 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,672 | $9,195 | Implemented |
UA0078 # 05 Y:2012 | 05 | 2012 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $10,180 | $0 | Implemented |
UA0078 # 06 Y:2012 | 06 | 2012 | REDUCE HEAT GAIN BY WINDOW TINTING | $4,732 | $16,800 | Not Implemented |
UA0078 # 07 Y:2012 | 07 | 2012 | INSTALL OCCUPANCY SENSORS | $2,072 | $1,706 | Implemented |
UA0071 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $62,618 | $96,027 | Not Implemented |
UA0071 # 02 Y:2011 | 02 | 2011 | INSTALL OCCUPANCY SENSORS | $2,105 | $2,719 | Implemented |
UA0071 # 03 Y:2011 | 03 | 2011 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $31,348 | $0 | Implemented |
UA0071 # 04 Y:2011 | 04 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $24,723 | $640 | Not Implemented |
UA0071 # 05 Y:2011 | 05 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,016 | $3,900 | Not Implemented |
UA0071 # 06 Y:2011 | 06 | 2011 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $20,451 | $66,050 | Not Implemented |
UA0071 # 07 Y:2011 | 07 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $22,837 | $1,752 | Not Implemented |
UA0069 # 01 Y:2011 | 01 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,023 | $800 | Not Implemented |