Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
143
matching recommendationsNAICS | 3363 | Motor Vehicle Parts Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0291 # 02 Y:2005 | 02 | 2005 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $18,138 | $19,073 | Not Implemented |
UM0291 # 01 Y:2005 | 01 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $20,293 | $9,000 | Implemented |
UM0291 # 05 Y:2005 | 05 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,841 | $1,490 | Not Implemented |
UM0291 # 08 Y:2005 | 08 | 2005 | INSTALL OCCUPANCY SENSORS | $396 | $150 | Not Implemented |
UM0291 # 07 Y:2005 | 07 | 2005 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,325 | $1,265 | Implemented |
UM0291 # 03 Y:2005 | 03 | 2005 | COVER OPEN TANKS | $4,518 | $2,366 | Implemented |
UM0291 # 06 Y:2005 | 06 | 2005 | USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES | $2,309 | $39,000 | Not Implemented |
UM0291 # 04 Y:2005 | 04 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,427 | $1,900 | Implemented |
MS0283 # 01 Y:2005 | 01 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $42,251 | $69,379 | Not Implemented |
MS0283 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $32,662 | $81,973 | Not Implemented |
MS0283 # 06 Y:2005 | 06 | 2005 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,320 | $236 | Not Implemented |
MS0283 # 08 Y:2005 | 08 | 2005 | INSTALL OCCUPANCY SENSORS | $402 | $556 | Not Implemented |
MS0283 # 07 Y:2005 | 07 | 2005 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,316 | $2,025 | Not Implemented |
MS0283 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,338 | $247 | Implemented |
MS0283 # 09 Y:2005 | 09 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $401 | $1,066 | Not Implemented |
MS0283 # 03 Y:2005 | 03 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $18,008 | $50,375 | Implemented |
MS0283 # 05 Y:2005 | 05 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,965 | $3,192 | Not Implemented |
IC0109 # 01 Y:2005 | 01 | 2005 | MODIFY WORKLOAD | $25,000 | $0 | Implemented |
IC0109 # 07 Y:2005 | 07 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $36,496 | $2,100 | Implemented |
IC0109 # 06 Y:2005 | 06 | 2005 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $37,809 | $131,160 | Not Implemented |
IC0109 # 05 Y:2005 | 05 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $1,239 | $400 | Implemented |
IC0109 # 04 Y:2005 | 04 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $17,632 | $22,464 | Not Implemented |
IC0109 # 03 Y:2005 | 03 | 2005 | REPLACE BOILER | $294,938 | $501,372 | Not Implemented |
IC0109 # 02 Y:2005 | 02 | 2005 | INSTALL WASTE HEAT BOILER TO PRODUCE STEAM | $437,212 | $3,259,200 | Not Implemented |
UM0289 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $859 | $2,663 | Not Implemented |