ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0871 # 05 Y:2012 | 05 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,057 | $0 | Not Implemented |
UD0871 # 09 Y:2012 | 09 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,384 | $1,000 | Not Implemented |
UD0871 # 10 Y:2012 | 10 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,963 | $0 | Not Implemented |
UD0871 # 07 Y:2012 | 07 | 2012 | DEVELOP A REPAIR/REPLACE POLICY | $1,103 | $2,498 | Not Implemented |
UD0871 # 08 Y:2012 | 08 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,075 | $0 | Not Implemented |
UD0871 # 12 Y:2012 | 12 | 2012 | INSULATE BARE EQUIPMENT | $1,754 | $5,700 | Not Implemented |
UD0871 # 11 Y:2012 | 11 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,709 | $500 | Not Implemented |
UD0871 # 13 Y:2012 | 13 | 2012 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,109 | $0 | Not Implemented |
UD0871 # 01 Y:2012 | 01 | 2012 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,905 | $0 | Not Implemented |
UD0871 # 04 Y:2012 | 04 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $27,260 | $0 | Not Implemented |
UD0871 # 06 Y:2012 | 06 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,649 | $0 | Not Implemented |
UD0871 # 02 Y:2012 | 02 | 2012 | INSTALL OCCUPANCY SENSORS | $597 | $950 | Not Implemented |
UD0871 # 03 Y:2012 | 03 | 2012 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $488 | $0 | Not Implemented |
UA3024 # 03 Y:2012 | 03 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $50,436 | $2,500 | Implemented |
UA3024 # 04 Y:2012 | 04 | 2012 | UPGRADE CONTROLS ON COMPRESSORS | $15,748 | $2,000 | Not Implemented |
UA3024 # 05 Y:2012 | 05 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $42,972 | $54,662 | Not Implemented |
UA3024 # 02 Y:2012 | 02 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $85,875 | $23,130 | Not Implemented |
UA3024 # 06 Y:2012 | 06 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $22,128 | $66,849 | Not Implemented |
UA3024 # 01 Y:2012 | 01 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $200,861 | $1,600 | Not Implemented |
UA3023 # 01 Y:2012 | 01 | 2012 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $90,505 | $55,107 | Not Implemented |
UA3023 # 02 Y:2012 | 02 | 2012 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $27,110 | $2,162 | Not Implemented |
UA3023 # 06 Y:2012 | 06 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $26,924 | $9,695 | Not Implemented |
UA3023 # 05 Y:2012 | 05 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $28,652 | $2,400 | Not Implemented |
UA3023 # 04 Y:2012 | 04 | 2012 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,914 | $180 | Implemented |
UA3023 # 03 Y:2012 | 03 | 2012 | INSTALL TIMERS AND/OR THERMOSTATS | $9,242 | $680 | Not Implemented |