Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
149
matching recommendationsNAICS | 3363 | Motor Vehicle Parts Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0548 # 02 Y:2015 | 02 | 2015 | REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY | $17,173 | $8,320 | Not Implemented |
IA0548 # 03 Y:2015 | 03 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $14,596 | $700 | Not Implemented |
IA0548 # 04 Y:2015 | 04 | 2015 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,432 | $23,803 | Not Implemented |
IA0548 # 05 Y:2015 | 05 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,809 | $140 | Not Implemented |
IA0548 # 06 Y:2015 | 06 | 2015 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $1,746 | $60 | Not Implemented |
IA0548 # 07 Y:2015 | 07 | 2015 | INSTALL OCCUPANCY SENSORS | $1,065 | $2,700 | Not Implemented |
IA0548 # 08 Y:2015 | 08 | 2015 | USE PHOTOCELL CONTROLS | $408 | $2,000 | Not Implemented |
IA0548 # 01 Y:2015 | 01 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,227 | $82,355 | Not Implemented |
UK1514 # 10 Y:2015 | 10 | 2015 | ADD AREA LIGHTING SWITCHES | $1,177 | $940 | Not Implemented |
UK1514 # 13 Y:2015 | 13 | 2015 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $10,092 | $6,632 | Not Implemented |
UK1514 # 03 Y:2015 | 03 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,483 | $2,000 | Implemented |
UK1514 # 08 Y:2015 | 08 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,674 | $5,574 | Not Implemented |
UK1514 # 05 Y:2015 | 05 | 2015 | TURN OFF EQUIPMENT WHEN NOT IN USE | $21,417 | $0 | Implemented |
UK1514 # 04 Y:2015 | 04 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,710 | $424 | Not Implemented |
UK1514 # 07 Y:2015 | 07 | 2015 | USE ONLY CERTIFIED MOTOR REPAIR SHOPS | $925 | $343 | Implemented |
UK1514 # 06 Y:2015 | 06 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $11,377 | $0 | Not Implemented |
UK1514 # 02 Y:2015 | 02 | 2015 | UPGRADE CONTROLS ON COMPRESSORS | $11,572 | $0 | Not Implemented |
UK1514 # 09 Y:2015 | 09 | 2015 | INSTALL OCCUPANCY SENSORS | $1,704 | $2,189 | Implemented |
UK1514 # 01 Y:2015 | 01 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $11,570 | $8,081 | Implemented |
UK1514 # 11 Y:2015 | 11 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,139 | $896 | Implemented |
UK1514 # 12 Y:2015 | 12 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,011 | $742 | Not Implemented |
UD0936 # 05 Y:2015 | 05 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,521 | $1,000 | Implemented |
UD0936 # 08 Y:2015 | 08 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,271 | $85,000 | Implemented |
UD0936 # 07 Y:2015 | 07 | 2015 | TURN OFF EQUIPMENT WHEN NOT IN USE | $530 | $1,480 | Implemented |
UD0936 # 03 Y:2015 | 03 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $17,704 | $6,000 | Not Implemented |