Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
126
matching recommendationsNAICS | 3363 | Motor Vehicle Parts Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NL0027 # 04 Y:2018 | 04 | 2018 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $607 | $1,050 | Not Implemented |
NL0027 # 05 Y:2018 | 05 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $326 | $1,000 | Implemented |
NL0027 # 02 Y:2018 | 02 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,840 | $74,980 | Implemented |
NL0027 # 01 Y:2018 | 01 | 2018 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $24,797 | $32,620 | Implemented |
NL0027 # 03 Y:2018 | 03 | 2018 | INSULATE BARE EQUIPMENT | $4,500 | $2,500 | Not Implemented |
NC0623 # 06 Y:2018 | 06 | 2018 | AVOID REWINDING MOTORS MORE THAN TWICE | $38,566 | $70,014 | Not Implemented |
NC0623 # 04 Y:2018 | 04 | 2018 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $6,478 | $16,800 | Implemented |
NC0623 # 05 Y:2018 | 05 | 2018 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $14,884 | $10,000 | Not Implemented |
NC0623 # 02 Y:2018 | 02 | 2018 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,322 | $900 | Implemented |
NC0623 # 03 Y:2018 | 03 | 2018 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,320 | $1,203 | Implemented |
NC0623 # 01 Y:2018 | 01 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,801 | $500 | Implemented |
WM0127 # 06 Y:2018 | 06 | 2018 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $2,944 | $3,500 | Not Implemented |
WM0127 # 02 Y:2018 | 02 | 2018 | USE SOLAR HEAT TO MAKE ELECTRICTY | $18,171 | $48,514 | Not Implemented |
WM0127 # 01 Y:2018 | 01 | 2018 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $36,186 | $37,500 | Not Implemented |
WM0127 # 08 Y:2018 | 08 | 2018 | INSULATE BARE EQUIPMENT | $2,412 | $666 | Not Implemented |
WM0127 # 04 Y:2018 | 04 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,136 | $2,000 | Not Implemented |
WM0127 # 11 Y:2018 | 11 | 2018 | USE PHOTOCELL CONTROLS | $256 | $47 | Not Implemented |
WM0127 # 05 Y:2018 | 05 | 2018 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $3,828 | $0 | Implemented |
WM0127 # 10 Y:2018 | 10 | 2018 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $600 | $1,511 | Implemented |
WM0127 # 07 Y:2018 | 07 | 2018 | USE RADIANT HEATER FOR SPOT HEATING | $2,840 | $2,472 | Not Implemented |
WM0127 # 09 Y:2018 | 09 | 2018 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $2,110 | $0 | Implemented |
WM0127 # 03 Y:2018 | 03 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,300 | $9,602 | Not Implemented |
SU0470 # 06 Y:2018 | 06 | 2018 | REDUCE VENTILATION AIR | $11,952 | $5,195 | Not Implemented |
SU0470 # 05 Y:2018 | 05 | 2018 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,049 | $83 | Not Implemented |
SU0470 # 04 Y:2018 | 04 | 2018 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $5,105 | $200 | Not Implemented |