Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
38
matching recommendationsNAICS | 336330 | Motor Vehicle Steering and Suspension Components (except Spring) Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IP0083 # 02 Y:2017 | 02 | 2017 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $15,779 | $5 | Not Implemented |
TT0192 # 10 Y:2017 | 10 | 2017 | DEVELOP A REPAIR/REPLACE POLICY | $796 | $1,453 | Not Implemented |
TT0192 # 09 Y:2017 | 09 | 2017 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $2,309 | $10,000 | Not Implemented |
TT0192 # 08 Y:2017 | 08 | 2017 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $3,741 | $8,000 | Not Implemented |
TT0192 # 07 Y:2017 | 07 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,001 | $3,000 | Not Implemented |
TT0192 # 06 Y:2017 | 06 | 2017 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $7,000 | $20,000 | Not Implemented |
TT0192 # 05 Y:2017 | 05 | 2017 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $7,432 | $9,000 | Not Implemented |
TT0192 # 04 Y:2017 | 04 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,492 | $11,000 | Not Implemented |
TT0192 # 03 Y:2017 | 03 | 2017 | INSTALL TIMERS AND/OR THERMOSTATS | $7,986 | $5,250 | Not Implemented |
TT0192 # 02 Y:2017 | 02 | 2017 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $12,730 | $18,400 | Implemented |
TT0192 # 01 Y:2017 | 01 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $175,487 | $344,898 | Implemented |
IP0083 # 10 Y:2017 | 10 | 2017 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $3,250 | $5,000 | Not Implemented |
IP0083 # 11 Y:2017 | 11 | 2017 | OPTIMIZE PLANT POWER FACTOR | $8,640 | $34,900 | Not Implemented |
IP0083 # 01 Y:2017 | 01 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $25,016 | $5 | Implemented |
IP0083 # 03 Y:2017 | 03 | 2017 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,290 | $0 | Implemented |
IP0083 # 04 Y:2017 | 04 | 2017 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,706 | $0 | Implemented |
IP0083 # 05 Y:2017 | 05 | 2017 | RECOVER WASTE HEAT FROM EQUIPMENT | $20,472 | $1,434 | Not Implemented |
IP0083 # 06 Y:2017 | 06 | 2017 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $15,077 | $1,296 | Implemented |
IP0083 # 07 Y:2017 | 07 | 2017 | INSTALL OCCUPANCY SENSORS | $13,276 | $7,860 | Implemented |
IP0083 # 08 Y:2017 | 08 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $23,581 | $23,044 | Implemented |
IP0083 # 09 Y:2017 | 09 | 2017 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,902 | $3,417 | Implemented |
UK1612 # 13 Y:2017 | 13 | 2017 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $1,400 | $422 | Not Implemented |
UK1612 # 12 Y:2017 | 12 | 2017 | INSULATE BARE EQUIPMENT | $1,083 | $1,584 | Not Implemented |
UK1612 # 11 Y:2017 | 11 | 2017 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $1,333 | $0 | Not Implemented |
UK1612 # 04 Y:2017 | 04 | 2017 | INSTALL SKYLIGHTS | $9,639 | $11,580 | Not Implemented |