Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

361

matching recommendations
Reset
NAICS 33635 Motor Vehicle Transmission and Power Train Parts Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TT0259 # 01 Y:2021 01 2021 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $300,781 $111,421 Implemented
WV0609 # 12 Y:2021 12 2021 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $487 $1,350 Implemented
WV0609 # 11 Y:2021 11 2021 INSULATE BARE EQUIPMENT $1,192 $1,293 Implemented
WV0609 # 10 Y:2021 10 2021 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,211 $3,175 Implemented
WV0609 # 09 Y:2021 09 2021 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $2,405 $1,500 Implemented
WV0609 # 08 Y:2021 08 2021 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,444 $7,620 Not Implemented
WV0609 # 07 Y:2021 07 2021 DEVELOP A REPAIR/REPLACE POLICY $3,040 $809 Implemented
WV0609 # 06 Y:2021 06 2021 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,657 $140 Implemented
WV0609 # 05 Y:2021 05 2021 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,695 $3,480 Implemented
WV0609 # 04 Y:2021 04 2021 UPGRADE CONTROLS ON COMPRESSORS $5,784 $14,420 Implemented
WV0609 # 03 Y:2021 03 2021 OPTIMIZE PLANT POWER FACTOR $9,397 $42,210 Not Implemented
WV0609 # 02 Y:2021 02 2021 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $13,040 $40,560 Not Implemented
WV0609 # 01 Y:2021 01 2021 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $78,485 $318,088 Not Implemented
TT0236 # 10 Y:2020 10 2020 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $206 $450 Not Implemented
TT0236 # 09 Y:2020 09 2020 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $984 $1,500 Not Implemented
TT0236 # 08 Y:2020 08 2020 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $1,653 $2,150 Not Implemented
TT0236 # 07 Y:2020 07 2020 CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS $1,908 $500 Not Implemented
TT0236 # 06 Y:2020 06 2020 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,574 $40 Not Implemented
TT0236 # 05 Y:2020 05 2020 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,447 $15,750 Not Implemented
TT0236 # 04 Y:2020 04 2020 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $8,754 $2,700 Not Implemented
TT0236 # 03 Y:2020 03 2020 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $20,250 $128,083 Implemented
TT0236 # 02 Y:2020 02 2020 ADOPT IN-HOUSE MATERIAL GENERATION $28,629 $16,000 Implemented
TT0236 # 01 Y:2020 01 2020 OPTIMIZE PLANT POWER FACTOR $28,173 $90,000 Not Implemented
IC0236 # 01 Y:2020 01 2020 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $49,924 $30,183 Implemented
IC0236 # 02 Y:2020 02 2020 BURN WOOD BY-PRODUCTS FOR HEAT $42,806 $9,522 Not Implemented