Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
361
matching recommendationsNAICS | 336350 | Motor Vehicle Transmission and Power Train Parts Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0288 # 05 Y:2005 | 05 | 2005 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $656 | $0 | Implemented |
UM0288 # 07 Y:2005 | 07 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $159 | $25 | Implemented |
UM0288 # 08 Y:2005 | 08 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $141 | $300 | Not Implemented |
UM0288 # 09 Y:2005 | 09 | 2005 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $130 | $50 | Not Implemented |
UM0288 # 10 Y:2005 | 10 | 2005 | INSTALL OCCUPANCY SENSORS | $90 | $600 | Implemented |
UM0288 # 06 Y:2005 | 06 | 2005 | REDUCE VENTILATION AIR | $616 | $150 | Implemented |
UM0286 # 05 Y:2005 | 05 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,619 | $500 | Not Implemented |
UM0286 # 06 Y:2005 | 06 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,608 | $75 | Implemented |
UM0286 # 01 Y:2005 | 01 | 2005 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $9,539 | $27,000 | Not Implemented |
UM0286 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,301 | $13,476 | Not Implemented |
UM0286 # 03 Y:2005 | 03 | 2005 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,775 | $1,900 | Implemented |
UM0286 # 07 Y:2005 | 07 | 2005 | INSTALL OCCUPANCY SENSORS | $618 | $736 | Not Implemented |
UM0286 # 08 Y:2005 | 08 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $352 | $1,000 | Not Implemented |
UM0286 # 09 Y:2005 | 09 | 2005 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $100 | $45 | Implemented |
UM0286 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,376 | $450 | Implemented |
UM0284 # 07 Y:2005 | 07 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $339 | $1,000 | Not Implemented |
UM0284 # 06 Y:2005 | 06 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,360 | $0 | Not Implemented |
UM0284 # 05 Y:2005 | 05 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,954 | $2,000 | Implemented |
UM0284 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,062 | $4,152 | Implemented |
UM0284 # 03 Y:2005 | 03 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,059 | $1,000 | Implemented |
UM0284 # 02 Y:2005 | 02 | 2005 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $9,488 | $11,000 | Not Implemented |
UM0284 # 01 Y:2005 | 01 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $32,977 | $1,275 | Implemented |
OK0702 # 01 Y:2005 | 01 | 2005 | REUSE / RECYCLE/ SELL RUBBER PRODUCTS | $22,000 | $6,600 | Not Implemented |
OK0702 # 02 Y:2005 | 02 | 2005 | USE POWER DURING OFF-PEAK PERIODS | $21,518 | $6,899 | Not Implemented |
OK0702 # 03 Y:2005 | 03 | 2005 | INSTALL OCCUPANCY SENSORS | $1,148 | $582 | Not Implemented |