Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
507
matching recommendationsNAICS | 336370 | Motor Vehicle Metal Stamping |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0299 # 06 Y:2006 | 06 | 2006 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $1,389 | $2,750 | Not Implemented |
UM0299 # 07 Y:2006 | 07 | 2006 | INSTALL SKYLIGHTS | $208 | $184 | Implemented |
NC0290 # 01 Y:2004 | 01 | 2004 | INSTALL REFRIGERATION SYSTEM TO COOL PRODUCT | $145,703 | $276,000 | Implemented |
NC0290 # 02 Y:2004 | 02 | 2004 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $9,371 | $4,079 | Not Implemented |
NC0290 # 03 Y:2004 | 03 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,085 | $5,500 | Not Implemented |
NC0290 # 04 Y:2004 | 04 | 2004 | INSULATE BARE EQUIPMENT | $2,865 | $9,174 | Not Implemented |
NC0290 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,206 | $2,269 | Not Implemented |
NC0290 # 06 Y:2004 | 06 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $612 | $100 | Implemented |
NC0290 # 07 Y:2004 | 07 | 2004 | INSTALL / REPAIR INSULATION ON STEAM LINES | $10,346 | $2,533 | Implemented |
UM0258 # 01 Y:2004 | 01 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $29,426 | $500 | Not Implemented |
UM0258 # 02 Y:2004 | 02 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $15,300 | $15,300 | Not Implemented |
UM0258 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,545 | $1,275 | Not Implemented |
UM0258 # 04 Y:2004 | 04 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,828 | $900 | Not Implemented |
UM0258 # 05 Y:2004 | 05 | 2004 | INSTALL OCCUPANCY SENSORS | $4,117 | $7,220 | Not Implemented |
UM0258 # 06 Y:2004 | 06 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,963 | $2,000 | Not Implemented |
UM0258 # 07 Y:2004 | 07 | 2004 | INSTALL OCCUPANCY SENSORS | $2,720 | $5,925 | Not Implemented |
UM0258 # 08 Y:2004 | 08 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,480 | $500 | Not Implemented |
UM0257 # 01 Y:2004 | 01 | 2004 | USE RADIANT HEATER FOR SPOT HEATING | $10,326 | $10,958 | Implemented |
UM0257 # 02 Y:2004 | 02 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,305 | $9,817 | Not Implemented |
UM0257 # 03 Y:2004 | 03 | 2004 | UPGRADE CONTROLS ON COMPRESSORS | $2,448 | $300 | Implemented |
UM0257 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,370 | $300 | Implemented |
UM0257 # 05 Y:2004 | 05 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $737 | $200 | Implemented |
UM0256 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $16,404 | $385 | Not Implemented |
UM0256 # 02 Y:2004 | 02 | 2004 | REDUCE VENTILATION AIR | $11,361 | $500 | Not Implemented |
UM0256 # 03 Y:2004 | 03 | 2004 | INSTALL OCCUPANCY SENSORS | $10,111 | $5,310 | Not Implemented |