Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
507
matching recommendationsNAICS | 336370 | Motor Vehicle Metal Stamping |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0548 # 01 Y:2015 | 01 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,227 | $82,355 | Not Implemented |
IA0548 # 02 Y:2015 | 02 | 2015 | REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY | $17,173 | $8,320 | Not Implemented |
IA0548 # 03 Y:2015 | 03 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $14,596 | $700 | Not Implemented |
IA0548 # 04 Y:2015 | 04 | 2015 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,432 | $23,803 | Not Implemented |
IA0548 # 05 Y:2015 | 05 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,809 | $140 | Not Implemented |
IA0548 # 06 Y:2015 | 06 | 2015 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $1,746 | $60 | Not Implemented |
IA0548 # 07 Y:2015 | 07 | 2015 | INSTALL OCCUPANCY SENSORS | $1,065 | $2,700 | Not Implemented |
IA0548 # 08 Y:2015 | 08 | 2015 | USE PHOTOCELL CONTROLS | $408 | $2,000 | Not Implemented |
WV0511 # 01 Y:2015 | 01 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $34,159 | $150,000 | Not Implemented |
WV0511 # 02 Y:2015 | 02 | 2015 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $19,864 | $40,000 | Not Implemented |
WV0511 # 03 Y:2015 | 03 | 2015 | UPGRADE CONTROLS ON COMPRESSORS | $16,424 | $20,442 | Not Implemented |
WV0511 # 04 Y:2015 | 04 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $15,254 | $2,007 | Implemented |
WV0511 # 05 Y:2015 | 05 | 2015 | REDUCE VENTILATION AIR | $14,480 | $15,000 | Not Implemented |
WV0511 # 06 Y:2015 | 06 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,417 | $15,818 | Implemented |
WV0511 # 07 Y:2015 | 07 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $9,476 | $0 | Implemented |
WV0511 # 08 Y:2015 | 08 | 2015 | FILTER AND REUSE HYDRAULIC OIL | $9,274 | $12,449 | Not Implemented |
WV0511 # 09 Y:2015 | 09 | 2015 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,429 | $15,050 | Not Implemented |
WV0511 # 10 Y:2015 | 10 | 2015 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $3,475 | $618 | Implemented |
WV0511 # 11 Y:2015 | 11 | 2015 | DEVELOP A REPAIR/REPLACE POLICY | $1,478 | $677 | Implemented |
WV0511 # 12 Y:2015 | 12 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $759 | $30 | Implemented |
WV0511 # 13 Y:2015 | 13 | 2015 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $500 | $1,000 | Implemented |
UK1501 # 01 Y:2015 | 01 | 2015 | OPTIMIZE PLANT POWER FACTOR | $2,481 | $2,300 | Not Implemented |
UK1501 # 02 Y:2015 | 02 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $18,106 | $0 | Not Implemented |
UK1501 # 03 Y:2015 | 03 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,967 | $500 | Implemented |
UK1501 # 04 Y:2015 | 04 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,186 | $7,500 | Not Implemented |