Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

66

matching recommendations
Reset
NAICS 336390 Other Motor Vehicle Parts Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TT0167 # 10 Y:2016 10 2016 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $815 $2,500 Not Implemented
TT0167 # 09 Y:2016 09 2016 INSTALL TIMERS AND/OR THERMOSTATS $1,481 $500 Not Implemented
TT0167 # 08 Y:2016 08 2016 RECOVER WASTE HEAT FROM EQUIPMENT $1,764 $500 Implemented
TT0167 # 07 Y:2016 07 2016 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,887 $3,000 Implemented
TT0167 # 06 Y:2016 06 2016 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $5,213 $900 Not Implemented
TT0167 # 05 Y:2016 05 2016 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $5,407 $125 Implemented
TT0167 # 04 Y:2016 04 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,188 $170,642 Implemented
TT0167 # 03 Y:2016 03 2016 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $20,627 $5,200 Not Implemented
TT0167 # 02 Y:2016 02 2016 OPTIMIZE PLANT POWER FACTOR $27,708 $28,000 Implemented
TT0098 # 05 Y:2012 05 2012 REPAIR AND ELIMINATE STEAM LEAKS $7,381 $980 Implemented
TT0098 # 04 Y:2012 04 2012 USE SOLAR HEAT TO HEAT MAKE-UP AIR $5,814 $43,695 Not Implemented
TT0098 # 03 Y:2012 03 2012 DE-ENERGIZE EXCESS TRANSFORMER CAPACITY $1,898 $5,525 Not Implemented
TT0098 # 02 Y:2012 02 2012 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,222 $2,320 Implemented
TT0098 # 01 Y:2012 01 2012 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $1,053 $1,116 Implemented
TT0097 # 03 Y:2012 03 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $63,167 $106,204 Implemented
TT0097 # 02 Y:2012 02 2012 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $25,306 $19,700 Not Implemented
TT0097 # 01 Y:2012 01 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $62,026 $78,780 Implemented
TT0060 # 03 Y:2011 03 2011 INSTALL EQUIPMENT TO UTILIZE WASTE FUEL $51,500 $98,000 Not Implemented
TT0060 # 01 Y:2011 01 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,900 $23,000 Not Implemented
TT0060 # 07 Y:2011 07 2011 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $28,000 $53,000 Not Implemented
TT0060 # 08 Y:2011 08 2011 REVISE SMOKE CLEANUP FROM OPERATIONS $22,900 $20,000 Not Implemented
TT0060 # 09 Y:2011 09 2011 INSTALL TIMERS AND/OR THERMOSTATS $9,800 $200 Not Implemented
TT0060 # 10 Y:2011 10 2011 INSTALL TIMERS AND/OR THERMOSTATS $3,700 $1,600 Not Implemented
TT0060 # 11 Y:2011 11 2011 INSTALL TIMERS AND/OR THERMOSTATS $500 $600 Not Implemented
TT0060 # 12 Y:2011 12 2011 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $1,280 $0 Not Implemented