Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
764
matching recommendationsNAICS | 3364 | Aerospace Product and Parts Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0889 # 03 Y:2014 | 03 | 2014 | INSTALL TIMERS AND/OR THERMOSTATS | $10,189 | $4,650 | Implemented |
OK0889 # 09 Y:2014 | 09 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,124 | $239 | Implemented |
OK0889 # 10 Y:2014 | 10 | 2014 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $2,920 | $10,599 | Implemented |
OK0894 # 04 Y:2014 | 04 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $853 | $551 | Implemented |
OK0894 # 05 Y:2014 | 05 | 2014 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $543 | $1,111 | Implemented |
OK0894 # 06 Y:2014 | 06 | 2014 | INSTALL TIMERS AND/OR THERMOSTATS | $9,056 | $2,750 | Implemented |
OK0894 # 07 Y:2014 | 07 | 2014 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $9,286 | $6,400 | Implemented |
OK0894 # 08 Y:2014 | 08 | 2014 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,062 | $1,409 | Implemented |
OK0894 # 11 Y:2014 | 11 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,260 | $2,090 | Implemented |
TT0139 # 02 Y:2014 | 02 | 2014 | DISCONNECT BALLASTS | $280 | $100 | Implemented |
TT0139 # 03 Y:2014 | 03 | 2014 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $13,460 | $500 | Implemented |
OK0887 # 01 Y:2014 | 01 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $36,397 | $35,374 | Implemented |
OK0887 # 02 Y:2014 | 02 | 2014 | INSTALL OCCUPANCY SENSORS | $7,219 | $3,969 | Implemented |
OK0887 # 03 Y:2014 | 03 | 2014 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $8,717 | $3,613 | Implemented |
OK0887 # 04 Y:2014 | 04 | 2014 | INSTALL OCCUPANCY SENSORS | $1,814 | $8,926 | Implemented |
OK0887 # 05 Y:2014 | 05 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,474 | $11,975 | Implemented |
OK0887 # 06 Y:2014 | 06 | 2014 | INSTALL TIMERS AND/OR THERMOSTATS | $13,990 | $0 | Implemented |
OK0887 # 07 Y:2014 | 07 | 2014 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,993 | $0 | Implemented |
OK0880 # 03 Y:2014 | 03 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,983 | $61,440 | Implemented |
BS0030 # 01 Y:2014 | 01 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,042 | $1,697 | Implemented |
SD0479 # 03 Y:2014 | 03 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $45,591 | $59,600 | Implemented |
SD0479 # 05 Y:2014 | 05 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $14,299 | $21,315 | Implemented |
SD0480 # 04 Y:2014 | 04 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,662 | $300 | Implemented |
MA0723 # 01 Y:2014 | 01 | 2014 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $23,304 | $90,000 | Implemented |
MA0723 # 02 Y:2014 | 02 | 2014 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $20,745 | $110,500 | Implemented |