Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
379
matching recommendationsNAICS | 336412 | Aircraft Engine and Engine Parts Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0086 # 08 Y:2004 | 08 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,615 | $490 | Implemented |
TA0073 # 03 Y:2004 | 03 | 2004 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $9,225 | $60 | Implemented |
TA0073 # 01 Y:2004 | 01 | 2004 | UPGRADE CONTROLS ON COMPRESSORS | $22,670 | $760 | Implemented |
TA0073 # 02 Y:2004 | 02 | 2004 | UPGRADE CONTROLS ON COMPRESSORS | $18,180 | $16 | Implemented |
TA0073 # 04 Y:2004 | 04 | 2004 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $8,315 | $1,360 | Implemented |
TA0073 # 05 Y:2004 | 05 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,700 | $16 | Implemented |
TA0073 # 06 Y:2004 | 06 | 2004 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $4,180 | $630 | Implemented |
TA0073 # 07 Y:2004 | 07 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,450 | $120 | Implemented |
TA0073 # 08 Y:2004 | 08 | 2004 | INSULATE BARE EQUIPMENT | $2,400 | $640 | Implemented |
TA0073 # 09 Y:2004 | 09 | 2004 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $60,865 | $0 | Implemented |
TA0073 # 10 Y:2004 | 10 | 2004 | SHUT OFF AIR CONDITIONING IN WINTER HEATING SEASON | $56,500 | $0 | Implemented |
TA0073 # 11 Y:2004 | 11 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $16,200 | $0 | Implemented |
TA0073 # 12 Y:2004 | 12 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,400 | $0 | Not Implemented |
OK0656 # 01 Y:2003 | 01 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $10,706 | $5,000 | Not Implemented |
OK0656 # 02 Y:2003 | 02 | 2003 | DISCONNECT BALLASTS | $3,785 | $315 | Not Implemented |
OK0656 # 03 Y:2003 | 03 | 2003 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $56,437 | $28,000 | Not Implemented |
OK0656 # 04 Y:2003 | 04 | 2003 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $16,663 | $1,000 | Not Implemented |
OK0656 # 05 Y:2003 | 05 | 2003 | INSTALL SET-BACK TIMERS | $5,285 | $2,340 | Not Implemented |
OK0656 # 06 Y:2003 | 06 | 2003 | INSTALL OCCUPANCY SENSORS | $659 | $659 | Not Implemented |
OK0655 # 01 Y:2003 | 01 | 2003 | INSTALL SET-BACK TIMERS | $21,416 | $543 | Not Implemented |
OK0655 # 02 Y:2003 | 02 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,168 | $1,300 | Not Implemented |
OK0655 # 03 Y:2003 | 03 | 2003 | REPLACE BOILER | $45,804 | $53,815 | n/a |
OK0655 # 04 Y:2003 | 04 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $38,818 | $30,499 | Not Implemented |
OK0655 # 05 Y:2003 | 05 | 2003 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $5,749 | $25,000 | Not Implemented |
AM0426 # 01 Y:2003 | 01 | 2003 | REUSE RAGS UNTIL COMPLETELY SOILED | $5,330 | $0 | Not Implemented |