Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

966

matching recommendations
Reset
NAICS 3371 Household and Institutional Furniture and Kitchen Cabinet Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MI0052 # 01 Y:2003 01 2003 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $14,442 $372 Not Implemented
MI0052 # 02 Y:2003 02 2003 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $7,425 $422 Not Implemented
MI0052 # 03 Y:2003 03 2003 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $30,699 $1,000 Not Implemented
MI0052 # 04 Y:2003 04 2003 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $6,165 $3,837 Implemented
MI0052 # 05 Y:2003 05 2003 $233,064 $48,450 Implemented
TA0047 # 01 Y:2003 01 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $9,375 $1,040 Implemented
TA0047 # 02 Y:2003 02 2003 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $7,854 $0 Implemented
TA0047 # 03 Y:2003 03 2003 PAY UTILITY BILLS ON TIME $3,040 $0 Implemented
TA0047 # 04 Y:2003 04 2003 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,770 $0 Not Implemented
TA0047 # 05 Y:2003 05 2003 USE SYNTHETIC LUBRICANT $645 $0 Not Implemented
TA0047 # 06 Y:2003 06 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $530 $770 Implemented
TA0047 # 07 Y:2003 07 2003 TURN OFF EQUIPMENT WHEN NOT IN USE $400 $0 Implemented
TA0047 # 08 Y:2003 08 2003 DISCONNECT BALLASTS $115 $165 Not Implemented
MI0051 # 01 Y:2003 01 2003 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $387 $525 Implemented
MI0051 # 02 Y:2003 02 2003 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN $480 $969 Not Implemented
MI0051 # 03 Y:2003 03 2003 TURN OFF EQUIPMENT WHEN NOT IN USE $4,154 $0 Not Implemented