Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
274
matching recommendationsNAICS | 337110 | Wood Kitchen Cabinet and Countertop Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0200 # 03 Y:2018 | 03 | 2018 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $360 | $864 | Not Implemented |
UA0200 # 04 Y:2018 | 04 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,725 | $1,345 | Not Implemented |
UA0200 # 05 Y:2018 | 05 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,552 | $100 | Not Implemented |
UA0200 # 06 Y:2018 | 06 | 2018 | MODIFY STARTUP/SHUTDOWN TIMES | $15,674 | $0 | Not Implemented |
UA0200 # 02 Y:2018 | 02 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,466 | $2,082 | Not Implemented |
UA0200 # 01 Y:2018 | 01 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,573 | $35,360 | Not Implemented |
UK1701 # 12 Y:2017 | 12 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,682 | $5,300 | Not Implemented |
UK1701 # 01 Y:2017 | 01 | 2017 | USE ONLY CERTIFIED MOTOR REPAIR SHOPS | $10,415 | $8,440 | Not Implemented |
UK1701 # 02 Y:2017 | 02 | 2017 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $9,847 | $4,000 | Not Implemented |
UK1701 # 03 Y:2017 | 03 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,878 | $11,800 | Not Implemented |
UK1701 # 04 Y:2017 | 04 | 2017 | INSTALL OCCUPANCY SENSORS | $257 | $384 | Not Implemented |
UK1701 # 05 Y:2017 | 05 | 2017 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,902 | $10,000 | Not Implemented |
UK1701 # 06 Y:2017 | 06 | 2017 | INSTALL DRY SPRINKLER SYSTEM OR OTHER METHOD TO REDUCE HEATING REQUIREMENTS | $1,690 | $2,875 | Not Implemented |
UK1701 # 07 Y:2017 | 07 | 2017 | LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE | $3,158 | $393 | Not Implemented |
UK1701 # 09 Y:2017 | 09 | 2017 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,426 | $1,350 | Not Implemented |
UK1701 # 10 Y:2017 | 10 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,915 | $0 | Not Implemented |
UK1701 # 11 Y:2017 | 11 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,452 | $2,100 | Not Implemented |
UK1701 # 13 Y:2017 | 13 | 2017 | USE PHOTOCELL CONTROLS | $1,070 | $800 | Not Implemented |
UK1701 # 08 Y:2017 | 08 | 2017 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,875 | $1,500 | Not Implemented |
UA0163 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $54,002 | $184,407 | Not Implemented |
UA0163 # 01 Y:2016 | 01 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $42,679 | $9,795 | Implemented |
UA0163 # 05 Y:2016 | 05 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,032 | $900 | Implemented |
UA0163 # 02 Y:2016 | 02 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $18,730 | $500 | Not Implemented |
UA0163 # 04 Y:2016 | 04 | 2016 | USE RADIANT HEATER FOR SPOT HEATING | $8,072 | $23,240 | Not Implemented |
CO0714 # 04 Y:2015 | 04 | 2015 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $9,310 | $36,000 | n/a |