Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
45
matching recommendationsNAICS | 33721 | Office Furniture (including Fixtures) Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0486 # 04 Y:2017 | 04 | 2017 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $342 | $1,500 | n/a |
UM0486 # 03 Y:2017 | 03 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $20,120 | $18,000 | n/a |
UM0486 # 02 Y:2017 | 02 | 2017 | INSTALL OCCUPANCY SENSORS | $896 | $2,400 | n/a |
UM0486 # 01 Y:2017 | 01 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,932 | $3,000 | n/a |
SD0546 # 01 Y:2017 | 01 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,392 | $25,659 | Implemented |
SD0546 # 03 Y:2017 | 03 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,431 | $6,068 | Implemented |
SD0546 # 02 Y:2017 | 02 | 2017 | USE PHOTOCELL CONTROLS | $8,753 | $17,253 | Implemented |
SD0546 # 05 Y:2017 | 05 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $989 | $400 | Implemented |
SD0546 # 06 Y:2017 | 06 | 2017 | INSTALL OCCUPANCY SENSORS | $419 | $1,000 | Implemented |
SD0546 # 04 Y:2017 | 04 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,299 | $2,500 | Implemented |
SD0542 # 06 Y:2017 | 06 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,162 | $600 | Not Implemented |
SD0542 # 05 Y:2017 | 05 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,740 | $1,500 | Implemented |
SD0542 # 04 Y:2017 | 04 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,078 | $14,300 | Not Implemented |
SD0542 # 03 Y:2017 | 03 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,743 | $11,288 | Implemented |
SD0542 # 02 Y:2017 | 02 | 2017 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $11,069 | $31,000 | Implemented |
SD0542 # 01 Y:2017 | 01 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $17,070 | $9,000 | Not Implemented |
SD0542 # 07 Y:2017 | 07 | 2017 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $1,935 | $1,833 | Not Implemented |
SD0542 # 08 Y:2017 | 08 | 2017 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,153 | $2,288 | Implemented |
SD0542 # 09 Y:2017 | 09 | 2017 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $967 | $850 | Not Implemented |
NC0591 # 06 Y:2017 | 06 | 2017 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $10,119 | $20,000 | Not Implemented |
NC0591 # 05 Y:2017 | 05 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,208 | $200 | Implemented |
NC0591 # 04 Y:2017 | 04 | 2017 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $9,474 | $24,000 | Implemented |
NC0591 # 03 Y:2017 | 03 | 2017 | USE PHOTOCELL CONTROLS | $52 | $100 | Implemented |
NC0591 # 02 Y:2017 | 02 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,501 | $4,590 | Implemented |
NC0591 # 01 Y:2017 | 01 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $30,408 | $87,579 | Implemented |