Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
136
matching recommendationsNAICS | 3379 | Other Furniture Related Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UK1913 # 08 Y:2019 | 08 | 2019 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $243 | $127 | Implemented |
UK1913 # 06 Y:2019 | 06 | 2019 | INSTALL OCCUPANCY SENSORS | $333 | $1,120 | Implemented |
MI0330 # 05 Y:2018 | 05 | 2018 | USE PHOTOCELL CONTROLS | $7,073 | $2,875 | Implemented |
MI0330 # 12 Y:2018 | 12 | 2018 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $608 | $756 | Implemented |
MI0330 # 11 Y:2018 | 11 | 2018 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $794 | $1,833 | Implemented |
MI0330 # 10 Y:2018 | 10 | 2018 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,190 | $1,160 | Not Implemented |
MI0330 # 09 Y:2018 | 09 | 2018 | INSULATE BARE EQUIPMENT | $1,778 | $1,722 | Not Implemented |
MI0330 # 08 Y:2018 | 08 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,223 | $7,807 | Implemented |
MI0330 # 07 Y:2018 | 07 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,299 | $2,670 | Implemented |
MI0330 # 06 Y:2018 | 06 | 2018 | INSTALL OCCUPANCY SENSORS | $5,537 | $7,669 | Implemented |
MI0330 # 04 Y:2018 | 04 | 2018 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $11,303 | $7,234 | Implemented |
MI0330 # 03 Y:2018 | 03 | 2018 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $14,180 | $480 | Implemented |
MI0330 # 02 Y:2018 | 02 | 2018 | INCREASE EFFICIENCY OF TRUCKS | $16,500 | $12,760 | Implemented |
MI0330 # 01 Y:2018 | 01 | 2018 | TURN OFF EQUIPMENT WHEN NOT IN USE | $29,294 | $1,300 | Implemented |
NC0600 # 03 Y:2017 | 03 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $383 | $200 | Implemented |
NC0600 # 02 Y:2017 | 02 | 2017 | INSTALL OCCUPANCY SENSORS | $191 | $850 | Implemented |
NC0600 # 01 Y:2017 | 01 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,705 | $10,366 | Implemented |
NC0600 # 04 Y:2017 | 04 | 2017 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $650 | $1,200 | Implemented |
NC0600 # 05 Y:2017 | 05 | 2017 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $8,798 | $500 | Not Implemented |
TT0108 # 03 Y:2013 | 03 | 2013 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,110 | $1,110 | Not Implemented |
TT0108 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,126 | $10,709 | Implemented |
TT0108 # 04 Y:2013 | 04 | 2013 | REPAIR AND ELIMINATE STEAM LEAKS | $4,000 | $980 | Implemented |
TT0108 # 02 Y:2013 | 02 | 2013 | CONSIDER POWER LOSS AS WELL AS INITIAL LOADS AND LOAD GROWTH IN DOWN-SIZING TRANSFORMERS | $5,367 | $8,075 | Not Implemented |
MZ0102 # 01 Y:2012 | 01 | 2012 | INSTALL OCCUPANCY SENSORS | $930 | $700 | Implemented |
MZ0102 # 02 Y:2012 | 02 | 2012 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $9,776 | $10,060 | Not Implemented |