Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
226
matching recommendationsNAICS | 339 | Miscellaneous Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0549 # 03 Y:2017 | 03 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,048 | $4,352 | Implemented |
SD0549 # 02 Y:2017 | 02 | 2017 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $16,056 | $3,882 | Implemented |
SD0549 # 01 Y:2017 | 01 | 2017 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $49,288 | $204,000 | Implemented |
SD0530 # 05 Y:2016 | 05 | 2016 | INSTALL SKYLIGHTS | $1,125 | $3,360 | Implemented |
SD0530 # 06 Y:2016 | 06 | 2016 | USE PHOTOCELL CONTROLS | $1,002 | $2,590 | Implemented |
SD0530 # 04 Y:2016 | 04 | 2016 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,261 | $861 | Implemented |
SD0530 # 03 Y:2016 | 03 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,876 | $200 | Implemented |
SD0530 # 02 Y:2016 | 02 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,344 | $1,500 | Implemented |
SD0530 # 01 Y:2016 | 01 | 2016 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $14,594 | $36,400 | Implemented |
SD0529 # 10 Y:2016 | 10 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $362 | $200 | Not Implemented |
SD0529 # 11 Y:2016 | 11 | 2016 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $280 | $767 | Not Implemented |
SD0529 # 01 Y:2016 | 01 | 2016 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $55,828 | $139,240 | Not Implemented |
SD0529 # 02 Y:2016 | 02 | 2016 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $41,516 | $13,343 | Not Implemented |
SD0529 # 03 Y:2016 | 03 | 2016 | ADOPT IN-HOUSE MATERIAL GENERATION | $9,790 | $15,235 | Not Implemented |
SD0529 # 04 Y:2016 | 04 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,076 | $29,064 | Not Implemented |
SD0529 # 05 Y:2016 | 05 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,155 | $5,524 | Not Implemented |
SD0529 # 06 Y:2016 | 06 | 2016 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,558 | $760 | Not Implemented |
SD0529 # 08 Y:2016 | 08 | 2016 | INSTALL OCCUPANCY SENSORS | $883 | $2,510 | Not Implemented |
SD0529 # 09 Y:2016 | 09 | 2016 | INSTALL TIMERS AND/OR THERMOSTATS | $629 | $344 | Not Implemented |
SD0529 # 07 Y:2016 | 07 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,189 | $1,000 | Not Implemented |
SF0466 # 01 Y:2015 | 01 | 2015 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $18,438 | $0 | Not Implemented |
SF0466 # 05 Y:2015 | 05 | 2015 | INSTALL OCCUPANCY SENSORS | $5,556 | $6,409 | Implemented |
SF0466 # 06 Y:2015 | 06 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,026 | $4,733 | Implemented |
SF0466 # 03 Y:2015 | 03 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,885 | $5,614 | Implemented |
SF0466 # 04 Y:2015 | 04 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,752 | $2,224 | Implemented |