Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
158
matching recommendationsNAICS | 339 | Miscellaneous Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0558 # 10 Y:2015 | 10 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $288 | $372 | Implemented |
NC0558 # 08 Y:2015 | 08 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,031 | $227 | Implemented |
NC0558 # 06 Y:2015 | 06 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $44 | $120 | Not Implemented |
NC0558 # 07 Y:2015 | 07 | 2015 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $63,599 | $250,000 | Not Implemented |
NC0558 # 09 Y:2015 | 09 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $296 | $80 | Implemented |
NC0558 # 01 Y:2015 | 01 | 2015 | RECOVER WASTE HEAT FROM EQUIPMENT | $28,923 | $17,820 | Not Implemented |
NC0558 # 12 Y:2015 | 12 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $320 | $1,595 | Implemented |
NC0558 # 11 Y:2015 | 11 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $145 | $716 | Implemented |
NC0558 # 02 Y:2015 | 02 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,925 | $300 | Implemented |
NC0558 # 05 Y:2015 | 05 | 2015 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,947 | $6,425 | Implemented |
NC0558 # 03 Y:2015 | 03 | 2015 | RECOVER WASTE HEAT FROM EQUIPMENT | $16,078 | $5,000 | Implemented |
NC0558 # 04 Y:2015 | 04 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,981 | $1,000 | Not Implemented |
MZ0199 # 02 Y:2015 | 02 | 2015 | CONDENSE OPERATION INTO ONE BUILDING | $19,376 | $2,500 | Not Implemented |
MZ0199 # 01 Y:2015 | 01 | 2015 | CONDENSE OPERATION INTO ONE BUILDING | $14,201 | $28,800 | Not Implemented |
MZ0199 # 06 Y:2015 | 06 | 2015 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $4,502 | $27,000 | Not Implemented |
MZ0199 # 03 Y:2015 | 03 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $31,470 | $116,250 | Not Implemented |
MZ0199 # 04 Y:2015 | 04 | 2015 | INSTALL OCCUPANCY SENSORS | $1,508 | $440 | Not Implemented |
MZ0199 # 05 Y:2015 | 05 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $279 | $20 | Not Implemented |
IP0049 # 01 Y:2015 | 01 | 2015 | PAY BILLS ON TIME TO AVOID LATE FEES | $4,118 | $0 | Implemented |
IP0049 # 11 Y:2015 | 11 | 2015 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $3,976 | $21,474 | Implemented |
IP0049 # 06 Y:2015 | 06 | 2015 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $5,511 | $4,400 | Not Implemented |
IP0049 # 04 Y:2015 | 04 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,009 | $70 | Implemented |
IP0049 # 02 Y:2015 | 02 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,197 | $8 | Implemented |
IP0049 # 05 Y:2015 | 05 | 2015 | INSTALL OCCUPANCY SENSORS | $1,359 | $770 | Not Implemented |
IP0049 # 07 Y:2015 | 07 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $223 | $283 | Not Implemented |