Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,372
matching recommendationsNAICS | 3399 | Other Miscellaneous Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0455 # 01 Y:2010 | 01 | 2010 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $11,148 | $1,000 | Implemented |
IA0455 # 02 Y:2010 | 02 | 2010 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $2,026 | $620 | Not Implemented |
IA0455 # 03 Y:2010 | 03 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $562 | $14 | Implemented |
IA0455 # 04 Y:2010 | 04 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,132 | $14 | Not Implemented |
IA0455 # 05 Y:2010 | 05 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,112 | $240 | Implemented |
IA0455 # 06 Y:2010 | 06 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,817 | $3,837 | Not Implemented |
IA0455 # 07 Y:2010 | 07 | 2010 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $165 | $112 | Implemented |
IA0455 # 08 Y:2010 | 08 | 2010 | INSTALL OCCUPANCY SENSORS | $6,632 | $9,702 | Implemented |
IA0455 # 09 Y:2010 | 09 | 2010 | INSTALL OCCUPANCY SENSORS | $1,331 | $3,960 | Implemented |
IA0455 # 10 Y:2010 | 10 | 2010 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $28,440 | $1,320 | Not Implemented |
IA0455 # 11 Y:2010 | 11 | 2010 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $1,067 | $2,556 | Not Implemented |
IA0455 # 12 Y:2010 | 12 | 2010 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,138 | $4,417 | Implemented |
TT0057 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,600 | $7,100 | Not Implemented |
TT0057 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,100 | $13,100 | Not Implemented |
TT0057 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $31,000 | $128,200 | Not Implemented |
TT0057 # 04 Y:2010 | 04 | 2010 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,685 | $2,500 | Not Implemented |
TT0057 # 05 Y:2010 | 05 | 2010 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $9,680 | $5,000 | Not Implemented |
TT0057 # 06 Y:2010 | 06 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,445 | $25 | Not Implemented |
TT0057 # 07 Y:2010 | 07 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,175 | $4,900 | Not Implemented |
OK0793 # 01 Y:2010 | 01 | 2010 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $88,705 | $104,400 | Implemented |
OK0793 # 02 Y:2010 | 02 | 2010 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $150,096 | $1,969,500 | Not Implemented |
OK0793 # 03 Y:2010 | 03 | 2010 | INSTALL REPLACEMENT DOORS | $1,246 | $33,150 | Not Implemented |
OK0793 # 04 Y:2010 | 04 | 2010 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $217,752 | $100,000 | Not Implemented |
OK0793 # 05 Y:2010 | 05 | 2010 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $104,850 | $134,480 | Not Implemented |
OK0793 # 06 Y:2010 | 06 | 2010 | INSTALL OCCUPANCY SENSORS | $8,717 | $17,813 | Implemented |