Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,352

matching recommendations
Reset
NAICS 3399 Other Miscellaneous Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SU0221 # 05 Y:2005 05 2005 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $7,835 $444 Not Implemented
SU0221 # 06 Y:2005 06 2005 INSTALL TURBULATORS $1,056 $271 Not Implemented
SU0221 # 07 Y:2005 07 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,388 $2,015 Implemented
SU0221 # 08 Y:2005 08 2005 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,125 $5,000 Not Implemented
SU0221 # 09 Y:2005 09 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $129 $1,155 Implemented
SU0221 # 10 Y:2005 10 2005 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $259 $721 Implemented
SU0221 # 11 Y:2005 11 2005 INSTALL OCCUPANCY SENSORS $96 $391 Implemented
WV0325 # 01 Y:2005 01 2005 USE RADIANT HEATER FOR SPOT HEATING $16,088 $12,504 Not Implemented
WV0325 # 02 Y:2005 02 2005 OPTIMIZE PLANT POWER FACTOR $10,956 $11,550 Not Implemented
WV0325 # 03 Y:2005 03 2005 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $7,144 $662 Implemented
WV0325 # 04 Y:2005 04 2005 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $7,050 $653 Implemented
WV0325 # 05 Y:2005 05 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,009 $0 Implemented
WV0325 # 06 Y:2005 06 2005 RECOVER WASTE HEAT FROM EQUIPMENT $3,529 $408 Not Implemented
WV0325 # 07 Y:2005 07 2005 DEVELOP A REPAIR/REPLACE POLICY $2,990 $257 Implemented
WV0325 # 08 Y:2005 08 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,637 $420 Implemented
WV0325 # 09 Y:2005 09 2005 INSTALL OCCUPANCY SENSORS $851 $426 Implemented
WV0325 # 10 Y:2005 10 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $832 $2,612 Implemented
WV0325 # 11 Y:2005 11 2005 UTILIZE A LESS EXPENSIVE COOLING METHOD $775 $521 Not Implemented
WV0325 # 12 Y:2005 12 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $756 $260 Implemented
WV0325 # 13 Y:2005 13 2005 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $416 $276 Not Implemented
MS0281 # 01 Y:2005 01 2005 BURN A LESS EXPENSIVE GRADE OF FUEL $79,041 $295,888 Not Implemented
MS0281 # 02 Y:2005 02 2005 COMBINE UTILITY METERS $12,247 $0 Not Implemented
MS0281 # 03 Y:2005 03 2005 INSTALL OCCUPANCY SENSORS $2,683 $1,211 Not Implemented
MS0281 # 04 Y:2005 04 2005 AIR CONDITION ONLY SPACE NECESSARY $2,668 $800 Not Implemented
MS0281 # 05 Y:2005 05 2005 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,603 $2,508 Not Implemented