Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
23
matching recommendationsNAICS | 3399 | Other Miscellaneous Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0798 # 02 Y:2019 | 02 | 2019 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $18,484 | $80,000 | Implemented |
MA0798 # 03 Y:2019 | 03 | 2019 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,569 | $8,930 | Not Implemented |
MA0798 # 04 Y:2019 | 04 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,904 | $2,765 | Not Implemented |
MA0798 # 05 Y:2019 | 05 | 2019 | INSULATE BARE EQUIPMENT | $3,333 | $1,801 | Implemented |
MA0798 # 06 Y:2019 | 06 | 2019 | INSTALL HEAT PIPES / RAISE COOLING SETPOINT | $2,585 | $500 | Not Implemented |
MA0798 # 07 Y:2019 | 07 | 2019 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,849 | $2,001 | Implemented |
MA0798 # 08 Y:2019 | 08 | 2019 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $922 | $978 | Not Implemented |
MA0798 # 09 Y:2019 | 09 | 2019 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $512 | $200 | Implemented |
MA0798 # 01 Y:2019 | 01 | 2019 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $39,625 | $48,500 | Implemented |
MAS017 # 03 Y:2012 | 03 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $511 | $200 | Not Implemented |
MAS017 # 02 Y:2012 | 02 | 2012 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $4,892 | $15,000 | Not Implemented |
MAS017 # 01 Y:2012 | 01 | 2012 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $34,566 | $10,000 | Implemented |
MAS016 # 01 Y:2012 | 01 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $21,510 | $5,600 | Implemented |
MAS016 # 02 Y:2012 | 02 | 2012 | RECOVER AND REUSE COOLING WATER | $79 | $375 | Not Implemented |
MAS016 # 03 Y:2012 | 03 | 2012 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $9,910 | $0 | Implemented |
MA0532 # 04 Y:2003 | 04 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,606 | $4,400 | Implemented |
MA0532 # 05 Y:2003 | 05 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,385 | $4,400 | Implemented |
MA0532 # 06 Y:2003 | 06 | 2003 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $1,627 | $1,845 | Implemented |
MA0532 # 07 Y:2003 | 07 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,580 | $0 | Implemented |
MA0532 # 08 Y:2003 | 08 | 2003 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $520 | $0 | Not Implemented |
MA0532 # 03 Y:2003 | 03 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,833 | $0 | Implemented |
MA0532 # 02 Y:2003 | 02 | 2003 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $38,956 | $84,895 | Not Implemented |
MA0532 # 01 Y:2003 | 01 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $67,039 | $7,300 | Implemented |