Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
41
matching recommendationsNAICS | 33999 | All Other Miscellaneous Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0535 # 02 Y:2022 | 02 | 2022 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $684 | $780 | Not Implemented |
LE0535 # 06 Y:2022 | 06 | 2022 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $75,870 | $448,000 | Not Implemented |
LE0535 # 04 Y:2022 | 04 | 2022 | UPGRADE OBSOLETE EQUIPMENT | $246,141 | $750,000 | Not Implemented |
LE0535 # 03 Y:2022 | 03 | 2022 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,728 | $2,200 | Not Implemented |
LE0535 # 01 Y:2022 | 01 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,826 | $6,362 | Not Implemented |
LE0535 # 05 Y:2022 | 05 | 2022 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $44,811 | $140,000 | Not Implemented |
LE0481 # 09 Y:2019 | 09 | 2019 | RECOVER WASTE HEAT FROM EQUIPMENT | $390 | $1,850 | Implemented |
LE0481 # 08 Y:2019 | 08 | 2019 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $2,376 | $10,000 | Not Implemented |
LE0481 # 07 Y:2019 | 07 | 2019 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $13,688 | $55,000 | Implemented |
LE0481 # 06 Y:2019 | 06 | 2019 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $842 | $3,200 | Not Implemented |
LE0481 # 05 Y:2019 | 05 | 2019 | CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS | $50,429 | $162,000 | Implemented |
LE0481 # 04 Y:2019 | 04 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,547 | $11,688 | Implemented |
LE0481 # 03 Y:2019 | 03 | 2019 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $42,460 | $57,500 | Not Implemented |
LE0481 # 02 Y:2019 | 02 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,696 | $14,000 | Not Implemented |
LE0481 # 01 Y:2019 | 01 | 2019 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $7,057 | $40 | Implemented |
LE0466 # 04 Y:2018 | 04 | 2018 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $158 | $180 | Not Implemented |
LE0466 # 05 Y:2018 | 05 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,119 | $7,950 | Not Implemented |
LE0466 # 03 Y:2018 | 03 | 2018 | BURN A LESS EXPENSIVE GRADE OF FUEL | $53,204 | $20,000 | Not Implemented |
LE0466 # 02 Y:2018 | 02 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,835 | $750 | Not Implemented |
LE0466 # 01 Y:2018 | 01 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $482 | $40 | Not Implemented |
LE0462 # 05 Y:2018 | 05 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,454 | $24,417 | Implemented |
LE0462 # 04 Y:2018 | 04 | 2018 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,005 | $2,000 | Not Implemented |
LE0462 # 03 Y:2018 | 03 | 2018 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $226 | $355 | Implemented |
LE0462 # 02 Y:2018 | 02 | 2018 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $15,808 | $20,000 | Not Implemented |
LE0462 # 01 Y:2018 | 01 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,915 | $1,000 | Implemented |