Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
266
matching recommendationsNAICS | 5111 | Newspaper, Periodical, Book, and Directory Publishers |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0298 # 07 Y:2005 | 07 | 2005 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $43,910 | $29,800 | Not Implemented |
SF0294 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,133 | $0 | Implemented |
SF0294 # 02 Y:2004 | 02 | 2004 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,624 | $0 | Not Implemented |
SF0294 # 03 Y:2004 | 03 | 2004 | INSTALL SPECTRAL REFLECTORS / DELAMP | $1,702 | $0 | Not Implemented |
SF0294 # 04 Y:2004 | 04 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $33,414 | $22,970 | Implemented |
SF0294 # 05 Y:2004 | 05 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,833 | $2,526 | Not Implemented |
SF0294 # 06 Y:2004 | 06 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $20,595 | $32,955 | Not Implemented |
SF0294 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,895 | $3,045 | Not Implemented |
SF0294 # 08 Y:2004 | 08 | 2004 | USE PHOTOCELL CONTROLS | $803 | $1,378 | Not Implemented |
SF0294 # 09 Y:2004 | 09 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,917 | $4,620 | Not Implemented |
SF0294 # 10 Y:2004 | 10 | 2004 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $6,054 | $0 | Not Implemented |
SF0294 # 11 Y:2004 | 11 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $31,801 | $29,800 | Not Implemented |
AS0387 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,518 | $500 | Not Implemented |
AS0387 # 02 Y:2004 | 02 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,736 | $60 | Not Implemented |
AS0387 # 03 Y:2004 | 03 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,601 | $14,813 | n/a |
AS0387 # 04 Y:2004 | 04 | 2004 | INSTALL OCCUPANCY SENSORS | $309 | $675 | Not Implemented |
AS0387 # 05 Y:2004 | 05 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,451 | $2,911 | Implemented |
AS0387 # 06 Y:2004 | 06 | 2004 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $9,180 | $10,083 | n/a |
AS0387 # 07 Y:2004 | 07 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,704 | $60 | Implemented |
SU0190 # 01 Y:2004 | 01 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,548 | $0 | Implemented |
SU0190 # 02 Y:2004 | 02 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $3,782 | $0 | Implemented |
SU0190 # 03 Y:2004 | 03 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $205 | $0 | Implemented |
SU0190 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $891 | $180 | Implemented |
SU0190 # 05 Y:2004 | 05 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $97 | $108 | Implemented |
SU0190 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $361 | $500 | Not Implemented |