Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,728
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KG0069 # 15 Y:1996 | 15 | 1996 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $177,789 | $30,000 | Implemented |
SF0101 # 01 Y:1996 | 01 | 1996 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $3,884 | $9,200 | Implemented |
SF0101 # 02 Y:1996 | 02 | 1996 | REPAIR AND ELIMINATE STEAM LEAKS | $2,060 | $250 | Implemented |
SF0101 # 03 Y:1996 | 03 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $828 | $150 | Implemented |
SF0101 # 04 Y:1996 | 04 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $590 | $1,016 | Implemented |
SF0101 # 05 Y:1996 | 05 | 1996 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $346 | $308 | Implemented |
SF0101 # 06 Y:1996 | 06 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $688 | $889 | Implemented |
SF0101 # 07 Y:1996 | 07 | 1996 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $5,740 | $780 | Implemented |
SF0101 # 08 Y:1996 | 08 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,156 | $250 | Implemented |
NC0102 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $764 | $2,500 | Implemented |
NC0102 # 04 Y:1996 | 04 | 1996 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,100 | $700 | Implemented |
NC0102 # 06 Y:1996 | 06 | 1996 | USE OTHER WASTE CONCENTRATION METHODS | $3,239 | $5,000 | Implemented |
OR0279 # 01 Y:1996 | 01 | 1996 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $1,604 | $0 | Implemented |
OR0279 # 03 Y:1996 | 03 | 1996 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $4,754 | $750 | Implemented |
OR0279 # 05 Y:1996 | 05 | 1996 | KEEP BOILER TUBES CLEAN | $1,349 | $1,500 | Implemented |
DS0067 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $444 | $4,230 | Implemented |
DS0067 # 04 Y:1996 | 04 | 1996 | OPTIMIZE PLANT POWER FACTOR | $9,685 | $6,735 | Implemented |
DS0067 # 05 Y:1996 | 05 | 1996 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $7,027 | $2,390 | Implemented |
AS0190 # 01 Y:1996 | 01 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,769 | $100 | Implemented |
AS0190 # 02 Y:1996 | 02 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,298 | $440 | Implemented |
AS0190 # 03 Y:1996 | 03 | 1996 | INSTALL OCCUPANCY SENSORS | $2,310 | $2,025 | Implemented |
AS0190 # 04 Y:1996 | 04 | 1996 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,913 | $5,700 | Implemented |
AS0190 # 06 Y:1996 | 06 | 1996 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $190,648 | $100,000 | Implemented |
AS0190 # 08 Y:1996 | 08 | 1996 | MINIMIZE WATER USAGE | $10,501 | $200 | Implemented |
UF0161 # 02 Y:1996 | 02 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $491 | $6,951 | Implemented |