IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

384

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UL0248 # 02 Y:2000 02 2000 USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS $51,600 $6,600 Implemented
UL0248 # 01 Y:2000 01 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,938 $15,352 Implemented
UL0244 # 01 Y:2000 01 2000 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $376 $13 Not Implemented
UL0244 # 02 Y:2000 02 2000 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $280 $20 Not Implemented
UL0244 # 03 Y:2000 03 2000 METER WASTE WATER $29,300 $2,858 Not Implemented
UL0244 # 05 Y:2000 05 2000 $185,698 $181,234 Not Implemented
UL0244 # 04 Y:2000 04 2000 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $3,542 $0 Not Implemented
UL0233 # 01 Y:1999 01 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,210 $50 Implemented
UL0233 # 02 Y:1999 02 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,678 $261 Not Implemented
UL0233 # 03 Y:1999 03 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $594 $0 Not Implemented
UL0233 # 04 Y:1999 04 1999 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $5,027 $4,475 Implemented
UL0233 # 05 Y:1999 05 1999 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $7,011 $9,500 Implemented
UL0233 # 06 Y:1999 06 1999 $10,120 $0 Not Implemented
UL0236 # 01 Y:1999 01 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,472 $20 Implemented
UL0236 # 02 Y:1999 02 1999 WASH AND REUSE RAGS ON-SITE $5,446 $11,315 Not Implemented
UL0236 # 03 Y:1999 03 1999 $48,322 $66,150 Not Implemented
UL0214 # 03 Y:1999 03 1999 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $5,476 $2,192 Not Implemented
UL0214 # 02 Y:1999 02 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,243 $119 Implemented
UL0214 # 01 Y:1999 01 1999 REPAIR OR REPLACE STEAM TRAPS $12,122 $6,950 Implemented
UL0213 # 03 Y:1999 03 1999 $93,500 $12,000 Implemented
UL0213 # 02 Y:1999 02 1999 MINIMIZE CONTAMINATION OF WATER BEFORE TREATMENT $21,700 $25,000 Implemented
UL0213 # 01 Y:1999 01 1999 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,043 $875 Not Implemented
UL0196 # 04 Y:1998 04 1998 $100,000 $10,000 Not Implemented
UL0196 # 03 Y:1998 03 1998 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $2,772 $0 Not Implemented
UL0196 # 02 Y:1998 02 1998 $10,845 $13,500 Not Implemented