Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
248
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0156 # 09 Y:1985 | 09 | 1985 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,323 | $0 | Not Implemented |
KU0156 # 10 Y:1985 | 10 | 1985 | ADD AIR SHIELDS TO TRUCKS TO INCREASE FUEL MILEAGE | $239 | $0 | Not Implemented |
KU0156 # 11 Y:1985 | 11 | 1985 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $141 | $40 | Not Implemented |
MA0022 # 01 Y:1985 | 01 | 1985 | HEAT WATER WITH EXHAUST HEAT | $2,163 | $1,875 | Not Implemented |
MA0022 # 02 Y:1985 | 02 | 1985 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $753 | $1,827 | Implemented |
MA0022 # 03 Y:1985 | 03 | 1985 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $160 | $154 | Implemented |
MA0022 # 04 Y:1985 | 04 | 1985 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $283 | $0 | Implemented |
MA0022 # 05 Y:1985 | 05 | 1985 | OPTIMIZE PLANT POWER FACTOR | $432 | $289 | Implemented |
MA0022 # 06 Y:1985 | 06 | 1985 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $1,060 | $1,190 | Not Implemented |
CO0016 # 01 Y:1985 | 01 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,955 | $1,548 | Implemented |
CO0016 # 02 Y:1985 | 02 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $7,070 | $300 | Not Implemented |
CO0016 # 03 Y:1985 | 03 | 1985 | INSTALL / REPAIR INSULATION ON STEAM LINES | $858 | $640 | Implemented |
CO0016 # 04 Y:1985 | 04 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $380 | $300 | Implemented |
CO0016 # 05 Y:1985 | 05 | 1985 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $121 | $219 | Not Implemented |
CO0016 # 06 Y:1985 | 06 | 1985 | INSULATE BARE EQUIPMENT | $149 | $170 | Not Implemented |
CO0016 # 07 Y:1985 | 07 | 1985 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $3,046 | $13,000 | Implemented |
CO0016 # 08 Y:1985 | 08 | 1985 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $235 | $200 | Implemented |
CO0016 # 09 Y:1985 | 09 | 1985 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $7,666 | $5,000 | Not Implemented |
CO0016 # 10 Y:1985 | 10 | 1985 | INSTALL TURBULATORS | $5,512 | $1,000 | Not Implemented |
CO0016 # 11 Y:1985 | 11 | 1985 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $1,879 | $2,500 | Not Implemented |
TS0005 # 01 Y:1985 | 01 | 1985 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $24,815 | $10,000 | Not Implemented |
TS0005 # 03 Y:1985 | 03 | 1985 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $8,775 | $18,500 | Not Implemented |
TS0005 # 04 Y:1985 | 04 | 1985 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $9,545 | $13,580 | Not Implemented |