ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LS1810 # 04 Y:2018 | 04 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $986 | $1,088 | Implemented |
LS1810 # 05 Y:2018 | 05 | 2018 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $37 | $55 | Not Implemented |
LS1810 # 06 Y:2018 | 06 | 2018 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $764 | $1,800 | Implemented |
LS1809 # 01 Y:2018 | 01 | 2018 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,090 | $100 | Not Implemented |
LS1809 # 02 Y:2018 | 02 | 2018 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $134 | $45 | Not Implemented |
LS1809 # 03 Y:2018 | 03 | 2018 | INSTALL OCCUPANCY SENSORS | $401 | $300 | Not Implemented |
LS1809 # 04 Y:2018 | 04 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,902 | $4,019 | Not Implemented |
LS1809 # 05 Y:2018 | 05 | 2018 | INSULATE BARE EQUIPMENT | $364 | $440 | Not Implemented |
LS1809 # 06 Y:2018 | 06 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $33 | $50 | Not Implemented |
LS1809 # 07 Y:2018 | 07 | 2018 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $6,145 | $11,000 | Not Implemented |
LS1806 # 01 Y:2018 | 01 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $168 | $100 | Not Implemented |
LS1806 # 02 Y:2018 | 02 | 2018 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $11 | $9 | Not Implemented |
LS1806 # 03 Y:2018 | 03 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,834 | $13,581 | Not Implemented |
LS1806 # 04 Y:2018 | 04 | 2018 | CONVERT LIQUID HEATERS FROM UNDERFIRING TO IMMERSION OR SUBMERSION HEATING | $1,519 | $6,300 | Not Implemented |
LS1803 # 01 Y:2018 | 01 | 2018 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $544 | $220 | Implemented |
LS1803 # 02 Y:2018 | 02 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $437 | $300 | Not Implemented |
LS1803 # 03 Y:2018 | 03 | 2018 | INSULATE BARE EQUIPMENT | $179 | $156 | Not Implemented |
LS1803 # 04 Y:2018 | 04 | 2018 | ELIMINATE/REDUCE AN OPERATION | $600 | $620 | Not Implemented |
LS1803 # 05 Y:2018 | 05 | 2018 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $39 | $95 | Not Implemented |
LS1803 # 06 Y:2018 | 06 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $577 | $2,755 | Implemented |
LS1803 # 07 Y:2018 | 07 | 2018 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $228 | $1,800 | Not Implemented |
LS0012 # 01 Y:2017 | 01 | 2017 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $28,766 | $12,000 | Not Implemented |
LS0012 # 02 Y:2017 | 02 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,205 | $920 | Not Implemented |
LS0012 # 03 Y:2017 | 03 | 2017 | INSULATE BARE EQUIPMENT | $993 | $548 | Not Implemented |
LS0012 # 04 Y:2017 | 04 | 2017 | IMPLEMENT A REGULAR MAINTENANCE PROGRAM TO REDUCE EMISSIONS FROM LEAKY VALVES AND PIPE FITTINGS | $21,748 | $15,200 | Not Implemented |