Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
630
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0377 # 07 Y:2008 | 07 | 2008 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $4,754 | $3,084 | Not Implemented |
WV0377 # 08 Y:2008 | 08 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,670 | $0 | Implemented |
WV0377 # 09 Y:2008 | 09 | 2008 | UPGRADE CONTROLS ON COMPRESSORS | $2,273 | $1,830 | Not Implemented |
WV0377 # 10 Y:2008 | 10 | 2008 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $1,858 | $7,053 | Not Implemented |
WV0377 # 11 Y:2008 | 11 | 2008 | INSULATE BARE EQUIPMENT | $1,335 | $710 | Implemented |
WV0377 # 12 Y:2008 | 12 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,192 | $1,202 | Implemented |
LE0267 # 01 Y:2008 | 01 | 2008 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $198,263 | $200,000 | Not Implemented |
LE0267 # 02 Y:2008 | 02 | 2008 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $41,140 | $6,000 | Implemented |
LE0267 # 03 Y:2008 | 03 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $36,169 | $30,000 | Implemented |
LE0267 # 04 Y:2008 | 04 | 2008 | REPAIR OR REPLACE STEAM TRAPS | $31,944 | $2,000 | Implemented |
LE0267 # 05 Y:2008 | 05 | 2008 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $21,795 | $30,000 | Not Implemented |
LE0267 # 06 Y:2008 | 06 | 2008 | CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS | $26,495 | $31,435 | Not Implemented |
LE0267 # 07 Y:2008 | 07 | 2008 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $9,200 | $3,000 | Implemented |
LE0267 # 08 Y:2008 | 08 | 2008 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $8,134 | $1,500 | Not Implemented |
LE0267 # 09 Y:2008 | 09 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,723 | $1,000 | Implemented |
LE0267 # 10 Y:2008 | 10 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,129 | $300,000 | Implemented |
LE0262 # 01 Y:2007 | 01 | 2007 | USE SOLAR HEAT TO MAKE ELECTRICTY | $204,947 | $1,684,540 | Not Implemented |
LE0262 # 02 Y:2007 | 02 | 2007 | REPAIR OR REPLACE STEAM TRAPS | $427,857 | $118,000 | Not Implemented |
LE0262 # 03 Y:2007 | 03 | 2007 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $173,079 | $300,000 | Not Implemented |
LE0262 # 04 Y:2007 | 04 | 2007 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $118,106 | $75,000 | Not Implemented |
LE0262 # 05 Y:2007 | 05 | 2007 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $40,484 | $1,000 | Not Implemented |
LE0262 # 06 Y:2007 | 06 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $36,726 | $36,000 | Not Implemented |
LE0262 # 07 Y:2007 | 07 | 2007 | REPAIR OR REPLACE STEAM TRAPS | $16,954 | $4,200 | Not Implemented |
LE0262 # 08 Y:2007 | 08 | 2007 | TURN OFF EQUIPMENT WHEN NOT IN USE | $13,938 | $500 | Not Implemented |
LE0262 # 09 Y:2007 | 09 | 2007 | INSTALL TIMERS AND/OR THERMOSTATS | $9,758 | $960 | Not Implemented |