Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,699
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0884 # 08 Y:2014 | 08 | 2014 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $1,563 | $280 | Implemented |
OK0884 # 09 Y:2014 | 09 | 2014 | INSULATE BARE EQUIPMENT | $451 | $189 | Not Implemented |
OK0884 # 10 Y:2014 | 10 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $17,109 | $30,860 | Not Implemented |
OK0884 # 11 Y:2014 | 11 | 2014 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $9,402 | $32,400 | Not Implemented |
OK0884 # 12 Y:2014 | 12 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,196 | $349 | Not Implemented |
OK0884 # 13 Y:2014 | 13 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $28,973 | $22,493 | Not Implemented |
OK0884 # 14 Y:2014 | 14 | 2014 | USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT | $296,879 | $1,365,235 | Not Implemented |
OR0632 # 01 Y:2014 | 01 | 2014 | IMPROVE COMBUSTION CONTROL CAPABILITY | $3,802 | $0 | Not Implemented |
OR0632 # 02 Y:2014 | 02 | 2014 | INSTALL OCCUPANCY SENSORS | $2,497 | $2,837 | Implemented |
OR0632 # 03 Y:2014 | 03 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,285 | $0 | Not Implemented |
OR0632 # 04 Y:2014 | 04 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $870 | $500 | Implemented |
OR0632 # 05 Y:2014 | 05 | 2014 | UPGRADE CONTROLS ON COMPRESSORS | $2,833 | $0 | Not Implemented |
OR0631 # 01 Y:2014 | 01 | 2014 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $11,360 | $250 | Implemented |
OR0631 # 02 Y:2014 | 02 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,168 | $5,544 | Not Implemented |
OR0631 # 03 Y:2014 | 03 | 2014 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,567 | $1,634 | Implemented |
OR0631 # 04 Y:2014 | 04 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $800 | $417 | Implemented |
MI0263 # 01 Y:2014 | 01 | 2014 | TURN OFF EQUIPMENT WHEN NOT IN USE | $23,147 | $3,600 | Not Implemented |
MI0263 # 02 Y:2014 | 02 | 2014 | TURN OFF EQUIPMENT WHEN NOT IN USE | $11,051 | $500 | Implemented |
MI0263 # 03 Y:2014 | 03 | 2014 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $13,762 | $28,000 | Not Implemented |
MI0263 # 04 Y:2014 | 04 | 2014 | HEAT WATER WITH EXHAUST HEAT | $6,564 | $8,859 | Not Implemented |
MI0263 # 05 Y:2014 | 05 | 2014 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $4,131 | $4,980 | Not Implemented |
MI0263 # 06 Y:2014 | 06 | 2014 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $3,052 | $560 | Implemented |
MI0263 # 07 Y:2014 | 07 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,377 | $10,770 | Not Implemented |
MI0263 # 08 Y:2014 | 08 | 2014 | INSTALL OCCUPANCY SENSORS | $1,643 | $497 | Implemented |
MI0263 # 09 Y:2014 | 09 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,472 | $1,660 | Implemented |