Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,034

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0255 # 05 Y:1995 05 1995 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $8,071 $0 Implemented
OR0255 # 06 Y:1995 06 1995 USE ABSORPTION, EXTRACTION TO REMOVE CONTAMINANTS $104,000 $250,000 Not Implemented
OR0255 # 07 Y:1995 07 1995 MINIMIZE WATER USAGE $5,927 $1,153 Implemented
OR0255 # 08 Y:1995 08 1995 MINIMIZE WATER USAGE $3,418 $148 Implemented
OR0255 # 09 Y:1995 09 1995 MINIMIZE WATER USAGE $3,344 $600 Not Implemented
OR0255 # 10 Y:1995 10 1995 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $1,952 $489 Not Implemented
OR0255 # 11 Y:1995 11 1995 MINIMIZE WATER USAGE $1,279 $434 Not Implemented
OR0243 # 01 Y:1995 01 1995 MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION $20,308 $0 Implemented
OR0243 # 02 Y:1995 02 1995 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,093 $500 Implemented
OR0243 # 03 Y:1995 03 1995 DIRECT WARMEST AIR TO COMBUSTION INTAKE $627 $198 Not Implemented
OR0243 # 04 Y:1995 04 1995 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $2,714 $2,108 Not Implemented
OR0243 # 05 Y:1995 05 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $278 $796 Implemented
OR0225 # 01 Y:1994 01 1994 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,420 $0 Not Implemented
OR0225 # 02 Y:1994 02 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,415 $10,402 Not Implemented
OR0225 # 03 Y:1994 03 1994 COMBINE UTILITY METERS $4,844 $2,863 Not Implemented
OR0225 # 04 Y:1994 04 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $18,649 $500 Implemented
OR0225 # 05 Y:1994 05 1994 OPTIMIZE PLANT POWER FACTOR $4,360 $13,200 Not Implemented
OR0221 # 01 Y:1994 01 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $9,806 $32,000 Not Implemented
OR0221 # 02 Y:1994 02 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $834 $1,840 Implemented
OR0221 # 03 Y:1994 03 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $137 $317 Implemented
OR0221 # 04 Y:1994 04 1994 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $317 $1,000 Not Implemented
OR0213 # 01 Y:1994 01 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $388 $2,028 Implemented
OR0213 # 02 Y:1994 02 1994 OPTIMIZE PLANT POWER FACTOR $5,154 $6,500 Not Implemented
OR0213 # 03 Y:1994 03 1994 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $1,889 $6,000 Not Implemented
OR0214 # 01 Y:1994 01 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $266 $0 Not Implemented