IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,034

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0073 # 04 Y:1989 04 1989 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $872 $883 Implemented
OR0073 # 05 Y:1989 05 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,024 $2,931 Implemented
OR0073 # 06 Y:1989 06 1989 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $770 $1,000 Implemented
OR0073 # 07 Y:1989 07 1989 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $1,207 $2,980 Not Implemented
OR0054 # 01 Y:1989 01 1989 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,028 $1,000 Implemented
OR0054 # 02 Y:1989 02 1989 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $1,259 $1,525 Not Implemented
OR0054 # 03 Y:1989 03 1989 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $147 $206 Implemented
OR0054 # 04 Y:1989 04 1989 DIRECT WARMEST AIR TO COMBUSTION INTAKE $349 $900 Implemented
OR0056 # 01 Y:1989 01 1989 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $252 $0 Implemented
OR0056 # 02 Y:1989 02 1989 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,873 $100 Implemented
OR0056 # 03 Y:1989 03 1989 MINIMIZE WATER USAGE $3,946 $1,683 Implemented
OR0056 # 04 Y:1989 04 1989 KEEP BOILER TUBES CLEAN $1,821 $100 Implemented
OR0056 # 05 Y:1989 05 1989 DIRECT WARMEST AIR TO COMBUSTION INTAKE $377 $310 Not Implemented
OR0056 # 06 Y:1989 06 1989 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $3,201 $2,750 Implemented
OR0056 # 07 Y:1989 07 1989 OPTIMIZE PLANT POWER FACTOR $294 $750 Not Implemented
OR0051 # 01 Y:1989 01 1989 INSTALL SET-BACK TIMERS $14,990 $0 Implemented
OR0051 # 02 Y:1989 02 1989 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $2,926 $0 Implemented
OR0051 # 03 Y:1989 03 1989 USE MINIMUM STEAM OPERATING PRESSURE $458 $0 Implemented
OR0051 # 04 Y:1989 04 1989 INSTALL STEAM TRAP $23,375 $2,335 Implemented
OR0051 # 05 Y:1989 05 1989 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $444 $500 Implemented
OR0051 # 06 Y:1989 06 1989 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $467 $503 Implemented
OR0051 # 07 Y:1989 07 1989 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $4,450 $8,000 Not Implemented
OR0051 # 08 Y:1989 08 1989 OPTIMIZE PLANT POWER FACTOR $2,544 $5,400 Not Implemented
OR0052 # 01 Y:1989 01 1989 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $880 $0 Implemented
OR0052 # 02 Y:1989 02 1989 INSTALL SET-BACK TIMERS $2,541 $0 Implemented