IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,034

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0052 # 03 Y:1989 03 1989 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $6,550 $2,400 Implemented
OR0052 # 04 Y:1989 04 1989 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $411 $320 Not Implemented
OR0052 # 05 Y:1989 05 1989 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,363 $500 Implemented
OR0052 # 06 Y:1989 06 1989 INSULATE BARE EQUIPMENT $375 $385 Not Implemented
OR0052 # 07 Y:1989 07 1989 REPAIR OR REPLACE STEAM TRAPS $8,216 $10,500 Implemented
OR0052 # 08 Y:1989 08 1989 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $259 $395 Implemented
OR0047 # 01 Y:1989 01 1989 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $8,348 $0 Implemented
OR0047 # 02 Y:1989 02 1989 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $5,777 $0 Implemented
OR0047 # 03 Y:1989 03 1989 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $3,193 $0 Implemented
OR0047 # 04 Y:1989 04 1989 INSTALL SET-BACK TIMERS $3,718 $0 Implemented
OR0047 # 05 Y:1989 05 1989 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,679 $500 Implemented
OR0047 # 06 Y:1989 06 1989 DIRECT WARMEST AIR TO COMBUSTION INTAKE $544 $650 Not Implemented
OR0047 # 07 Y:1989 07 1989 INSULATE FEEDWATER TANK $435 $658 Implemented
OR0047 # 08 Y:1989 08 1989 OPTIMIZE PLANT POWER FACTOR $3,159 $6,810 Implemented
OR0048 # 01 Y:1989 01 1989 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $519 $500 Not Implemented
OR0048 # 02 Y:1989 02 1989 RECOVER AND REUSE COOLING WATER $622 $316 Implemented
OR0048 # 03 Y:1989 03 1989 RECOVER AND REUSE COOLING WATER $473 $402 Implemented
OR0048 # 04 Y:1989 04 1989 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $135 $138 Not Implemented
OR0048 # 05 Y:1989 05 1989 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $1,545 $7,500 Implemented
OR0048 # 06 Y:1989 06 1989 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $10,327 $13,600 Not Implemented
OR0048 # 07 Y:1989 07 1989 OPTIMIZE PLANT POWER FACTOR $592 $1,500 Implemented
OR0041 # 01 Y:1988 01 1988 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $527 $0 Not Implemented
OR0041 # 02 Y:1988 02 1988 USE MINIMUM STEAM OPERATING PRESSURE $254 $0 Implemented
OR0041 # 03 Y:1988 03 1988 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $949 $300 Implemented
OR0041 # 04 Y:1988 04 1988 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $941 $475 Not Implemented