Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,647
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0434 # 06 Y:2011 | 06 | 2011 | INSTALL SKYLIGHTS | $11,302 | $26,616 | Not Implemented |
SD0432 # 01 Y:2011 | 01 | 2011 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,239 | $0 | Implemented |
SD0432 # 02 Y:2011 | 02 | 2011 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $2,059 | $800 | Implemented |
SD0432 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $214 | $100 | Not Implemented |
SD0432 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,412 | $800 | Not Implemented |
SD0432 # 05 Y:2011 | 05 | 2011 | INSTALL OCCUPANCY SENSORS | $204 | $427 | Implemented |
SD0432 # 06 Y:2011 | 06 | 2011 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $3,408 | $8,000 | Not Implemented |
SD0432 # 07 Y:2011 | 07 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,373 | $8,285 | Not Implemented |
SF0392 # 01 Y:2011 | 01 | 2011 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $215 | $541 | Implemented |
SF0392 # 02 Y:2011 | 02 | 2011 | INSTALL OCCUPANCY SENSORS | $533 | $1,128 | Implemented |
SF0392 # 03 Y:2011 | 03 | 2011 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,774 | $4,927 | Not Implemented |
SF0392 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,741 | $10,656 | Implemented |
SD0502 # 01 Y:2010 | 01 | 2010 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $17,800 | $10,000 | Implemented |
SD0502 # 02 Y:2010 | 02 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $12,170 | $1,000 | Implemented |
SD0502 # 03 Y:2010 | 03 | 2010 | INCREASE AMOUNT OF CONDENSATE RETURNED | $15,940 | $2,263 | Not Implemented |
SD0502 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $49,905 | $161,162 | Implemented |
SF0386 # 03 Y:2010 | 03 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,677 | $1,600 | Not Implemented |
SF0386 # 04 Y:2010 | 04 | 2010 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $3,507 | $7,500 | Not Implemented |
SF0386 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,553 | $40,720 | Not Implemented |
SF0386 # 06 Y:2010 | 06 | 2010 | INSTALL OCCUPANCY SENSORS | $5,315 | $18,821 | Not Implemented |
SF0386 # 07 Y:2010 | 07 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $217 | $461 | Not Implemented |
SF0386 # 01 Y:2010 | 01 | 2010 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $10,471 | $0 | Not Implemented |
SF0386 # 02 Y:2010 | 02 | 2010 | USE PHOTOCELL CONTROLS | $4,307 | $3,738 | Not Implemented |
SF0385 # 01 Y:2010 | 01 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,418 | $0 | Implemented |
SF0385 # 02 Y:2010 | 02 | 2010 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $12,270 | $0 | Implemented |