Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
207
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0186 # 07 Y:2001 | 07 | 2001 | HEAT WATER WITH EXHAUST HEAT | $12,268 | $10,846 | Implemented |
MS0186 # 08 Y:2001 | 08 | 2001 | APPLY FOR INVESTMENT INCENTIVES | $74 | $100 | Not Implemented |
MS0163 # 01 Y:2000 | 01 | 2000 | COMBINE UTILITY METERS | $18,393 | $1,834 | Not Implemented |
MS0163 # 02 Y:2000 | 02 | 2000 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,598 | $2,700 | Not Implemented |
MS0163 # 03 Y:2000 | 03 | 2000 | CLOSE OFF UNNEEDED STEAM LINES | $6,111 | $1,665 | Not Implemented |
MS0163 # 04 Y:2000 | 04 | 2000 | BURN WASTE OIL FOR HEAT | $1,653 | $2,161 | Not Implemented |
MS0163 # 05 Y:2000 | 05 | 2000 | METER WASTE WATER | $8,863 | $1,043 | Not Implemented |
MS0163 # 06 Y:2000 | 06 | 2000 | APPLY FOR INVESTMENT INCENTIVES | $620 | $50 | Not Implemented |
MS0162 # 01 Y:2000 | 01 | 2000 | INSULATE BARE EQUIPMENT | $575 | $371 | Not Implemented |
MS0162 # 02 Y:2000 | 02 | 2000 | INSTALL TIMERS AND/OR THERMOSTATS | $453 | $472 | Not Implemented |
MS0162 # 03 Y:2000 | 03 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $429 | $158 | Implemented |
MS0162 # 04 Y:2000 | 04 | 2000 | HEAT WATER WITH EXHAUST HEAT | $4,758 | $13,860 | Not Implemented |
MS0162 # 05 Y:2000 | 05 | 2000 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $3,175 | $2,450 | Implemented |
MS0162 # 06 Y:2000 | 06 | 2000 | APPLY FOR INVESTMENT INCENTIVES | $926 | $25 | Not Implemented |
MS0125 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,761 | $6,971 | Implemented |
MS0125 # 02 Y:1998 | 02 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,888 | $3,952 | Not Implemented |
MS0125 # 03 Y:1998 | 03 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $125 | $236 | Implemented |
MS0125 # 04 Y:1998 | 04 | 1998 | ELIMINATE/REDUCE AN OPERATION | $3,255 | $0 | Implemented |
MS0125 # 05 Y:1998 | 05 | 1998 | MINIMIZE WATER USAGE | $279 | $10 | Implemented |
MS0125 # 06 Y:1998 | 06 | 1998 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $5,878 | $14,990 | Not Implemented |
MS0125 # 07 Y:1998 | 07 | 1998 | PAY BILLS ON TIME TO AVOID LATE FEES | $813 | $324 | Implemented |
MS0111 # 01 Y:1998 | 01 | 1998 | OPTIMIZE PLANT POWER FACTOR | $23,520 | $9,000 | n/a |
MS0111 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,198 | $8,073 | n/a |
MS0111 # 03 Y:1998 | 03 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,589 | $2,068 | n/a |
MS0111 # 04 Y:1998 | 04 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $149 | $103 | n/a |