Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

366

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OD0151 # 01 Y:2000 01 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $855 $487 Not Implemented
OD0151 # 02 Y:2000 02 2000 INSTALL OCCUPANCY SENSORS $45 $95 Not Implemented
OD0151 # 03 Y:2000 03 2000 USE PHOTOCELL CONTROLS $194 $100 Not Implemented
OD0151 # 04 Y:2000 04 2000 INSTALL SKYLIGHTS $106 $180 Not Implemented
OD0151 # 05 Y:2000 05 2000 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,229 $1,815 Not Implemented
OD0151 # 06 Y:2000 06 2000 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $180 $725 Not Implemented
NC0180 # 01 Y:1999 01 1999 ADJUST BURNERS FOR EFFICIENT OPERATION $8,324 $2,000 Implemented
NC0180 # 02 Y:1999 02 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,282 $1,500 Implemented
NC0180 # 03 Y:1999 03 1999 RECOVER WASTE HEAT FROM EQUIPMENT $15,440 $53,360 Implemented
NC0180 # 04 Y:1999 04 1999 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $1,175 $3,250 Implemented
NC0180 # 05 Y:1999 05 1999 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $188 $300 Not Implemented
NC0180 # 06 Y:1999 06 1999 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $15,265 $1,500 Implemented
NC0180 # 07 Y:1999 07 1999 ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS $47,820 $68,000 Implemented
NC0169 # 01 Y:1999 01 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,315 $9,860 Implemented
NC0169 # 02 Y:1999 02 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,700 $9,240 Implemented
NC0169 # 03 Y:1999 03 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $167 $20 Not Implemented
NC0169 # 04 Y:1999 04 1999 ADJUST BURNERS FOR EFFICIENT OPERATION $2,154 $800 Implemented
NC0169 # 05 Y:1999 05 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $90 $90 Implemented
NC0169 # 06 Y:1999 06 1999 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $188 $300 Not Implemented
NC0169 # 07 Y:1999 07 1999 MODIFY PROCESS TO REDUCE MATERIAL USE/COST $56,250 $10,000 Implemented
NC0172 # 01 Y:1999 01 1999 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $125,000 $52,000 Not Implemented
NC0172 # 02 Y:1999 02 1999 OPERATE BOILERS ON HIGH FIRE SETTING $4,485 $0 Not Implemented
NC0172 # 03 Y:1999 03 1999 INSULATE BARE EQUIPMENT $636 $476 Not Implemented
NC0172 # 04 Y:1999 04 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $10,986 $40 Not Implemented
NC0172 # 05 Y:1999 05 1999 RECOVER WASTE HEAT FROM EQUIPMENT $71,741 $40,000 Not Implemented