Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,785
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0338 # 07 Y:1988 | 07 | 1988 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $518 | $710 | Not Implemented |
CO0112 # 01 Y:1988 | 01 | 1988 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $198 | $100 | Implemented |
CO0112 # 02 Y:1988 | 02 | 1988 | INSTALL / REPAIR INSULATION ON STEAM LINES | $5,919 | $9,000 | Implemented |
CO0112 # 03 Y:1988 | 03 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $776 | $0 | Implemented |
CO0112 # 04 Y:1988 | 04 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $89,563 | $4,000 | Implemented |
CO0112 # 05 Y:1988 | 05 | 1988 | BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT | $281,382 | $1,200,000 | Not Implemented |
CO0112 # 06 Y:1988 | 06 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $223 | $399 | Implemented |
AT0095 # 01 Y:1988 | 01 | 1988 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $5,220 | $500 | Not Implemented |
AT0095 # 02 Y:1988 | 02 | 1988 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $945 | $500 | Implemented |
AT0095 # 03 Y:1988 | 03 | 1988 | INSTALL TURBULATORS | $602 | $700 | Implemented |
AT0095 # 04 Y:1988 | 04 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $871 | $500 | Implemented |
AT0095 # 05 Y:1988 | 05 | 1988 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $516 | $900 | Implemented |
AT0095 # 06 Y:1988 | 06 | 1988 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $2,105 | $100 | Implemented |
AT0095 # 07 Y:1988 | 07 | 1988 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $996 | $0 | Not Implemented |
AT0095 # 08 Y:1988 | 08 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $524 | $476 | Implemented |
AT0095 # 09 Y:1988 | 09 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,185 | $0 | Implemented |
AT0095 # 10 Y:1988 | 10 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,861 | $1,315 | Implemented |
AM0025 # 01 Y:1988 | 01 | 1988 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $8,582 | $15,000 | Not Implemented |
AM0025 # 02 Y:1988 | 02 | 1988 | INSULATE BARE EQUIPMENT | $913 | $1,116 | Implemented |
AM0025 # 03 Y:1988 | 03 | 1988 | INSTALL SET-BACK TIMERS | $797 | $0 | Implemented |
AM0025 # 04 Y:1988 | 04 | 1988 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $422 | $0 | Implemented |
AM0025 # 05 Y:1988 | 05 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $72 | $72 | Implemented |
AM0025 # 06 Y:1988 | 06 | 1988 | INSTALL SET-BACK TIMERS | $159 | $0 | Implemented |
TN0332 # 01 Y:1988 | 01 | 1988 | USE MINIMUM STEAM OPERATING PRESSURE | $13,494 | $0 | Not Implemented |
TN0332 # 02 Y:1988 | 02 | 1988 | CLOSE OFF UNNEEDED STEAM LINES | $9,055 | $0 | Not Implemented |